CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions Fluid Volume Overload and Congestion in Heart Failure: Time to Reconsider Pathophysiology and How Volume Is Assessed Positive recommendation for angiotensin receptor/neprilysin inhibitor: First medication approval for heart failure without "reduced ejection fraction" Impact of intravascular ultrasound-guided percutaneous coronary intervention on long-term clinical outcomes in a real world population 2019 ACC Expert Consensus Decision Pathway on Risk Assessment, Management, and Clinical Trajectory of Patients Hospitalized With Heart Failure: A Report of the American College of Cardiology Solution Set Oversight Committee Outcomes with intravascular ultrasound-guided stent implantation: a meta-analysis of randomized trials in the era of drug-eluting stents Therapeutic Options for In-Stent Restenosis Optical frequency-domain imaging findings to predict good stent expansion after rotational atherectomy for severely calcified coronary lesions 6-Month Versus 12-Month Dual-Antiplatelet Therapy Following Long Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial Frailty Is Intertwined With Heart Failure: Mechanisms, Prevalence, Prognosis, Assessment, and Management

Original ResearchVolume 13, Issue 12, June 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

Coronary Calcification and Long-Term Outcomes According to Drug-Eluting Stent Generation

P Guedeney, BE Claessen, GW Stone et al. Keywords: 2nd generation DES vs. 1st generation DES; moderate or severe calcification lesions; 5-year outcome

ABSTRACT

OBJECTIVES - The aim of this study was to evaluate the long-term impact of coronary artery calcification (CAC) on outcomes after percutaneous coronary intervention and the respective performance of first- and second-generation drug-eluting stents (DES).


BACKGROUND - Whether contemporary DES have improved the long-term prognosis after percutaneous coronary intervention in lesions with severe CAC is unknown.


METHODS - Individual patient data were pooled from 18 randomized trials evaluating DES, categorized according to the presence of angiography core laboratory–confirmed moderate or severe CAC. Major endpoints were the patient-oriented composite endpoint (death, myocardial infarction [MI], or any revascularization) and the device-oriented composite endpoint of target lesion failure (cardiac death, target vessel MI, or ischemia-driven target lesion revascularization). Multivariate Cox proportional regression with study as a random effect was used to assess 5-year outcomes.


RESULTS - A total of 19,833 patients were included. Moderate or severe CAC was present in 1 or more target lesions in 6,211 patients (31.3%) and was associated with increased 5-year risk for the patient-oriented composite endpoint (adjusted hazard ratio [adjHR]: 1.12; 95% confidence interval [CI]: 1.05 to 1.20) and target lesion failure (adjHR: 1.21; 95% CI: 1.09 to 1.34), as well as death, MI, and ischemia-driven target lesion revascularization. In patients with CAC, use of second-generation DES compared with first-generation DES was associated with reductions in the 5-year risk for the patient-oriented composite endpoint (adjHR: 0.88; 95% CI: 0.78 to 1.00) and target lesion failure (adjHR: 0.73; 95% CI: 0.61 to 0.87), as well as death or MI, ischemia-driven target lesion revascularization, and stent thrombosis. The relative treatment effects of second-generation compared with first-generation DES were consistent in patients with and without moderate or severe CAC, although outcomes were consistently better with contemporary devices.


CONCLUSIONS - In this large-scale study, percutaneous coronary intervention of target lesion moderate or severe CAC was associated with adverse patient-oriented and device-oriented adverse outcomes at 5 years. These detrimental effects were mitigated with second-generation DES.