Antithrombotic Management of Elderly Patients With Coronary Artery Disease Intravascular Imaging and 12-Month Mortality After Unprotected Left Main Stem PCI: An Analysis From the British Cardiovascular Intervention Society Database Everolimus-eluting stent implantation for unprotected left main coronary artery stenosis. The PRECOMBAT-2 (Premier of Randomized Comparison of Bypass Surgery versus Angioplasty Using Sirolimus-Eluting Stent in Patients with Left Main Coronary Artery Disease) study Use of the Instantaneous Wave-free Ratio or Fractional Flow Reserve in PCI Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study The right ventricle in pulmonary hypertension Contemporary prevalence of pulmonary arterial hypertension in adult congenital heart disease following the updated clinical classification Optimizing outcomes during left main percutaneous coronary intervention with intravascular ultrasound and fractional flow reserve: the current state of evidence Safety of intermediate left main stenosis revascularization deferral based on fractional flow reserve and intravascular ultrasound: A systematic review and meta-regression including 908 deferred left main stenosis from 12 studies 2015 ESC/ERS Guidelines for the diagnosis and treatment of pulmonary hypertension: The Joint Task Force for the Diagnosis and Treatment of Pulmonary Hypertension of the European Society of Cardiology (ESC) and the European Respiratory Society (ERS): Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC), International Society for Heart and Lung Transplantation (ISHLT)

Original Research2020 Jul 6.

JOURNAL:Catheter Cardiovasc Interv . Article Link

Bioprosthetic valve oversizing is associated with increased risk of valve thrombosis following TAVR

TF Simpson, CV Tuohy, K Rajotte et al. Keywords: aortic valve stenosis; bioprosthesis; thrombosis; TAVR

ABSTRACT

BACKGROUND - Hypoattenuating leaflet thickening (HALT), the radiographic manifestation of transcatheter heart valve thrombosis, is commonly identified following transcatheter aortic valve replacement (TAVR) and associated with increased risk of stroke and structural valve deterioration. While anticoagulation effectively resolves HALT, routine use remains controversial. We aimed to identify hemodynamic, anatomic, and comorbid predictors of HALT.


METHODS - We evaluated consecutive patients with severe aortic stenosis who underwent TAVR with Edwards SAPIEN 3 bioprosthesis at a single center between June 1, 2018 and October 30, 2019. Patients on anticoagulation and those receiving valve-in-valve were excluded. Clinically driven computed tomography (CT) imaging was performed to assess for HALT at the discretion of the treating valve team.


RESULTS - A total of 78 patients with a mean age of 78 ± 10 years and STS risk score 5.5 ± 3.3% were analyzed. HALT was identified in 11 (14.1%) patients. Compared to controls, those with HALT had smaller annular areas, 435 ± 57 mm2vs. 489 ± 79 mm2(p = .032), but received comparable size valves. In multivariate regression, valve oversizing by more than 20% was associated with increased risk of HALT, OR 23.5, 95% CI 2.5-223, (p = .006). After initiation of anticoagulation, patients with HALT had similar rates of stroke, major bleeding, and all-cause mortality out to an average of 243 days.


CONCLUSIONS - In this pragmatic study of patients undergoing TAVR with SAPIEN 3 valves, we report the novel finding that oversizing by more than 20% was independently associated with increased risk of HALT. These findings warrant confirmation in larger and prospective trials