In patients with stable coronary heart disease, low-density lipoprotein-cholesterol levels < 70 mg/dL and glycosylated hemoglobin A1c < 7% are associated with lower major cardiovascular events Mediterranean Diet and the Association Between Air Pollution and Cardiovascular Disease Mortality Risk Coronary calcification in the diagnosis of coronary artery disease Clinical Risk Factors and Atherosclerotic Plaque Extent to Define Risk for Major Events in Patients Without Obstructive Coronary Artery Disease: The Long-Term Coronary Computed Tomography Angiography CONFIRM Registry Increased glycated albumin and decreased esRAGE levels in serum are related to negative coronary artery remodeling in patients with type 2 diabetes: an Intravascular ultrasound study Bioprosthetic valve oversizing is associated with increased risk of valve thrombosis following TAVR Health Status after Transcatheter vs. Surgical Aortic Valve Replacement in Low-Risk Patients with Aortic Stenosis Bridging the Gap Between Epigenetic and Genetic in PAH The Role of Vascular Imaging in Guiding Routine Percutaneous Coronary Interventions: A Meta-Analysis of Bare Metal Stent and Drug-Eluting Stent Trials Atherosclerosis — An Inflammatory Disease

Original Research2020 Jul 6.

JOURNAL:Catheter Cardiovasc Interv . Article Link

Bioprosthetic valve oversizing is associated with increased risk of valve thrombosis following TAVR

TF Simpson, CV Tuohy, K Rajotte et al. Keywords: aortic valve stenosis; bioprosthesis; thrombosis; TAVR

ABSTRACT

BACKGROUND - Hypoattenuating leaflet thickening (HALT), the radiographic manifestation of transcatheter heart valve thrombosis, is commonly identified following transcatheter aortic valve replacement (TAVR) and associated with increased risk of stroke and structural valve deterioration. While anticoagulation effectively resolves HALT, routine use remains controversial. We aimed to identify hemodynamic, anatomic, and comorbid predictors of HALT.


METHODS - We evaluated consecutive patients with severe aortic stenosis who underwent TAVR with Edwards SAPIEN 3 bioprosthesis at a single center between June 1, 2018 and October 30, 2019. Patients on anticoagulation and those receiving valve-in-valve were excluded. Clinically driven computed tomography (CT) imaging was performed to assess for HALT at the discretion of the treating valve team.


RESULTS - A total of 78 patients with a mean age of 78 ± 10 years and STS risk score 5.5 ± 3.3% were analyzed. HALT was identified in 11 (14.1%) patients. Compared to controls, those with HALT had smaller annular areas, 435 ± 57 mm2vs. 489 ± 79 mm2(p = .032), but received comparable size valves. In multivariate regression, valve oversizing by more than 20% was associated with increased risk of HALT, OR 23.5, 95% CI 2.5-223, (p = .006). After initiation of anticoagulation, patients with HALT had similar rates of stroke, major bleeding, and all-cause mortality out to an average of 243 days.


CONCLUSIONS - In this pragmatic study of patients undergoing TAVR with SAPIEN 3 valves, we report the novel finding that oversizing by more than 20% was independently associated with increased risk of HALT. These findings warrant confirmation in larger and prospective trials