CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Clinical Efficacy and Safety of Evolocumab in High-Risk Patients Receiving a Statin: Secondary Analysis of Patients With Low LDL Cholesterol Levels and in Those Already Receiving a Maximal-Potency Statin in a Randomized Clinical Trial High-sensitivity troponin in the evaluation of patients with suspected acute coronary syndrome: a stepped-wedge, cluster-randomised controlled trial Role of Low Endothelial Shear Stress and Plaque Characteristics in the Prediction of Nonculprit Major Adverse Cardiac Events: The PROSPECT Study Patient Characteristics Associated With Antianginal Medication Escalation and De-Escalation Following Chronic Total Occlusion Percutaneous Coronary Intervention: Insights From the OPEN CTO Registry Effect of a Restrictive vs Liberal Blood Transfusion Strategy on Major Cardiovascular Events Among Patients With Acute Myocardial Infarction and Anemia: The REALITY Randomized Clinical Trial The Potential Use of the Index of Microcirculatory Resistance to Guide Stratification of Patients for Adjunctive Therapy in Acute Myocardial Infarction A Combination of Allogeneic Stem Cells Promotes Cardiac Regeneration Relations between implementation of new treatments and improved outcomes in patients with non-ST-elevation myocardial infarction during the last 20 years: experiences from SWEDEHEART registry 1995 to 2014 Clinical and Angiographic Features of Patients With Out-of-Hospital Cardiac Arrest and Acute Myocardial Infarction Healed Culprit Plaques in Patients With Acute Coronary Syndromes

Original Research2020 Jul 6.

JOURNAL:Catheter Cardiovasc Interv . Article Link

Bioprosthetic valve oversizing is associated with increased risk of valve thrombosis following TAVR

TF Simpson, CV Tuohy, K Rajotte et al. Keywords: aortic valve stenosis; bioprosthesis; thrombosis; TAVR

ABSTRACT

BACKGROUND - Hypoattenuating leaflet thickening (HALT), the radiographic manifestation of transcatheter heart valve thrombosis, is commonly identified following transcatheter aortic valve replacement (TAVR) and associated with increased risk of stroke and structural valve deterioration. While anticoagulation effectively resolves HALT, routine use remains controversial. We aimed to identify hemodynamic, anatomic, and comorbid predictors of HALT.


METHODS - We evaluated consecutive patients with severe aortic stenosis who underwent TAVR with Edwards SAPIEN 3 bioprosthesis at a single center between June 1, 2018 and October 30, 2019. Patients on anticoagulation and those receiving valve-in-valve were excluded. Clinically driven computed tomography (CT) imaging was performed to assess for HALT at the discretion of the treating valve team.


RESULTS - A total of 78 patients with a mean age of 78 ± 10 years and STS risk score 5.5 ± 3.3% were analyzed. HALT was identified in 11 (14.1%) patients. Compared to controls, those with HALT had smaller annular areas, 435 ± 57 mm2vs. 489 ± 79 mm2(p = .032), but received comparable size valves. In multivariate regression, valve oversizing by more than 20% was associated with increased risk of HALT, OR 23.5, 95% CI 2.5-223, (p = .006). After initiation of anticoagulation, patients with HALT had similar rates of stroke, major bleeding, and all-cause mortality out to an average of 243 days.


CONCLUSIONS - In this pragmatic study of patients undergoing TAVR with SAPIEN 3 valves, we report the novel finding that oversizing by more than 20% was independently associated with increased risk of HALT. These findings warrant confirmation in larger and prospective trials