CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Drug-Coated Balloon-Only Percutaneous Coronary Intervention for the Treatment of De Novo Coronary Artery Disease: A Systematic Review Prediction of progression of coronary artery disease and clinical outcomes using vascular profiling of endothelial shear stress and arterial plaque characteristics: the PREDICTION Study Orbital atherectomy for treating de novo, severely calcified coronary lesions: 3-year results of the pivotal ORBIT II trial Drug-Coated Balloon Versus Drug-Eluting Stent for Small Coronary Vessel Disease: PICCOLETO II Randomized Clinical Trial Percutaneous Repair or Medical Treatment for Secondary Mitral Regurgitation: Outcomes at 2 years Treatment of Drug-Eluting Stent In-Stent Restenosis With Drug-Eluting Balloons: A Systematic Review and Meta-Analysis Percutaneous Pulmonary Angioplasty for Patients With Takayasu Arteritis and Pulmonary Hypertension Optical Coherence Tomography to Assess Proximal Side Optimization Technique in Crush Stenting Evolution of the Crush Technique for Bifurcation Stenting Fractional Flow Reserve–Guided PCI as Compared with Coronary Bypass Surgery

Clinical Trial2020 Aug 8.

JOURNAL:Cardiovasc Drugs Ther. Article Link

Metformin Lowers Body Weight But Fails to Increase Insulin Sensitivity in Chronic Heart Failure Patients without Diabetes: a Randomized, Double-Blind, Placebo-Controlled Study

AH Larsen, H Wiggers, Niels Jessen et al. Keywords: HF; hyperinsulinemic euglycemic clamp; Insulin sensitivity; metformin

ABSTRACT

PURPOSE - The glucose-lowering drug metformin has recently been shown to reduce myocardial oxygen consumption and increase myocardial efficiency in chronic heart failure (HF) patients without diabetes. However, it remains to be established whether these beneficial myocardial effects are associated with metformin-induced alterations in whole-body insulin sensitivity and substrate metabolism.


METHODS - Eighteen HF patients with reduced ejection fraction and without diabetes (median age, 65 (interquartile range 55–68); ejection fraction 39 ± 6%; HbA1c 5.5 to 6.4%) were randomized to receive metformin (n= 10) or placebo (n= 8) for 3 months. We studied the effects of metformin on whole-body insulin sensitivity using a two-step hyperinsulinemic euglycemic clamp incorporating isotope-labeled tracers of glucose, palmitate, and urea. Substrate metabolism and skeletal muscle mitochondrial respiratory capacity were determined by indirect calorimetry and high-resolution respirometry, and body composition was assessed by bioelectrical impedance analysis. The primary outcome measure was change in insulin sensitivity.


RESULTS - Compared with placebo, metformin treatment lowered mean glycated hemoglobin levels (absolute mean difference, − 0.2%; 95% CI − 0.3 to 0.0;p= 0.03), reduced body weight (− 2.8 kg; 95% CI − 5.0 to − 0.6;p= 0.02), and increased fasting glucagon levels (3.2 pmol L−1; 95% CI 0.4 to 6.0;p= 0.03). No changes were observed in whole-body insulin sensitivity, endogenous glucose production, and peripheral glucose disposal or oxidation with metformin. Equally, resting energy expenditure, lipid and urea turnover, and skeletal muscle mitochondrial respiratory capacity remained unaltered.


CONCLUSION - Increased myocardial efficiency during metformin treatment is not mediated through improvements in insulin action in HF patients without diabetes.


CLINICAL TRIAL REGISTRATION - URL: https://clinicaltrials.gov. Unique identifier: NCT02810132. Date of registration: June 22, 2016.