CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Nocturnal thoracic volume overload and post-discharge outcomes in patients hospitalized for acute heart failure Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement From Focal Lipid Storage to Systemic Inflammation Aliskiren, Enalapril, or Aliskiren and Enalapril in Heart Failure Bioprosthetic valve oversizing is associated with increased risk of valve thrombosis following TAVR Sex- and Race-Related Differences in Characteristics and Outcomes of Hospitalizations for Heart Failure With Preserved Ejection Fraction From Subclinical Atherosclerosis to Plaque Progression and Acute Coronary Events Suture- or Plug-Based Large-Bore Arteriotomy Closure: A Pilot Randomized Controlled Trial Health Status after Transcatheter vs. Surgical Aortic Valve Replacement in Low-Risk Patients with Aortic Stenosis Association of Statin Use With All-Cause and Cardiovascular Mortality in US Veterans 75 Years and Older

Clinical Trial2020 Aug 8.

JOURNAL:Cardiovasc Drugs Ther. Article Link

Metformin Lowers Body Weight But Fails to Increase Insulin Sensitivity in Chronic Heart Failure Patients without Diabetes: a Randomized, Double-Blind, Placebo-Controlled Study

AH Larsen, H Wiggers, Niels Jessen et al. Keywords: HF; hyperinsulinemic euglycemic clamp; Insulin sensitivity; metformin

ABSTRACT

PURPOSE - The glucose-lowering drug metformin has recently been shown to reduce myocardial oxygen consumption and increase myocardial efficiency in chronic heart failure (HF) patients without diabetes. However, it remains to be established whether these beneficial myocardial effects are associated with metformin-induced alterations in whole-body insulin sensitivity and substrate metabolism.


METHODS - Eighteen HF patients with reduced ejection fraction and without diabetes (median age, 65 (interquartile range 55–68); ejection fraction 39 ± 6%; HbA1c 5.5 to 6.4%) were randomized to receive metformin (n= 10) or placebo (n= 8) for 3 months. We studied the effects of metformin on whole-body insulin sensitivity using a two-step hyperinsulinemic euglycemic clamp incorporating isotope-labeled tracers of glucose, palmitate, and urea. Substrate metabolism and skeletal muscle mitochondrial respiratory capacity were determined by indirect calorimetry and high-resolution respirometry, and body composition was assessed by bioelectrical impedance analysis. The primary outcome measure was change in insulin sensitivity.


RESULTS - Compared with placebo, metformin treatment lowered mean glycated hemoglobin levels (absolute mean difference, − 0.2%; 95% CI − 0.3 to 0.0;p= 0.03), reduced body weight (− 2.8 kg; 95% CI − 5.0 to − 0.6;p= 0.02), and increased fasting glucagon levels (3.2 pmol L−1; 95% CI 0.4 to 6.0;p= 0.03). No changes were observed in whole-body insulin sensitivity, endogenous glucose production, and peripheral glucose disposal or oxidation with metformin. Equally, resting energy expenditure, lipid and urea turnover, and skeletal muscle mitochondrial respiratory capacity remained unaltered.


CONCLUSION - Increased myocardial efficiency during metformin treatment is not mediated through improvements in insulin action in HF patients without diabetes.


CLINICAL TRIAL REGISTRATION - URL: https://clinicaltrials.gov. Unique identifier: NCT02810132. Date of registration: June 22, 2016.