CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study Contemporary techniques in percutaneous coronary intervention for bifurcation lesions Drug-Coated Balloons for Coronary Artery Disease: Third Report of the International DCB Consensus Group Treatment of Very Small De Novo Coronary Artery Disease With 2.0 mm Drug-Coated Balloons Showed 1-Year Clinical Outcome Comparable With 2.0 mm Drug-Eluting Stents Influence of Local Myocardial Damage on Index of Microcirculatory Resistance and Fractional Flow Reserve in Target and Nontarget Vascular Territories in a Porcine Microvascular Injury Model Adaptive development of concomitant secondary mitral and tricuspid regurgitation after transcatheter aortic valve replacement Clinical and angiographic outcomes of coronary dissection after paclitaxel-coated balloon angioplasty for small vessel coronary artery disease Long-term efficacy and safety of drug-coated balloons versus drug-eluting stents for small coronary artery disease (BASKET-SMALL 2): 3-year follow-up of a randomised, non-inferiority trial Optical Coherence Tomography–Defined Plaque Vulnerability in Relation to Functional Stenosis Severity and Microvascular Dysfunction Drug-Coated Balloon-Only Percutaneous Coronary Intervention for the Treatment of De Novo Coronary Artery Disease: A Systematic Review

Review ArticleSeptember 9, 2020

JOURNAL:JAMA Cardiol. Article Link

Considerations for Optimal Device Selection in Transcatheter Aortic Valve Replacement: A Review

BE Claessen, GHL Tang, AS Kini et al. Keywords: TAVR; device selection; RCT

ABSTRACT

IMPORTANCE - Aortic valve stenosis (AS) is the most common manifestation of acquired valvular heart disease in developed countries. Several large-scale randomized clinical trials investigating the entire spectrum of patients with severe symptomatic AS from low to prohibitive risk have established transcatheter aortic valve replacement (TAVR) as a safe and effective alternative to surgical aortic valve replacement.


OBSERVATIONS - There are currently only 3 types of TAVR devices commercially available in the US, but several other valve types are undergoing clinical trials in the US. Because of fundamental differences in engineering features, each TAVR device type has specific strengths and limitations. This review aims to provide an overview of design features and clinical outcomes of various TAVR devices that are either commercially available or undergoing clinical investigation.


CONCLUSIONS AND RELEVANCE - Given the lack of large-scale head-to-head comparisons of various TAVR devices and the rapid development of new device iterations, there is insufficient evidence to claim superiority of one device type over another. Nonetheless, as each TAVR device has unique design characteristics, certain patient-related and anatomy-related factors may slightly favor one or several particular designs.