CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Relationship between intravascular ultrasound guidance and clinical outcomes after drug-eluting stents: the assessment of dual antiplatelet therapy with drug-eluting stents (ADAPT-DES) study Assessment of coronary atherosclerosis by IVUS and IVUS-based imaging modalities: progression and regression studies, tissue composition and beyond Positive recommendation for angiotensin receptor/neprilysin inhibitor: First medication approval for heart failure without "reduced ejection fraction" Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis 6-Month Versus 12-Month Dual-Antiplatelet Therapy Following Long Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial Phenomapping for Novel Classification of Heart Failure With Preserved Ejection Fraction Surgery Does Not Improve Survival in Patients With Isolated Severe Tricuspid Regurgitation Temporal Trends in Inpatient Use of Intravascular Imaging Among Patients Undergoing Percutaneous Coronary Intervention in the United States Derivation, Validation, and Prognostic Utility of a Prediction Rule for Nonresponse to Clopidogrel: The ABCD-GENE Score Cardiovascular biomarkers in patients with acute decompensated heart failure randomized to sacubitril-valsartan or enalapril in the PIONEER-HF trial

Review ArticleSeptember 9, 2020

JOURNAL:JAMA Cardiol. Article Link

Considerations for Optimal Device Selection in Transcatheter Aortic Valve Replacement: A Review

BE Claessen, GHL Tang, AS Kini et al. Keywords: TAVR; device selection; RCT

ABSTRACT

IMPORTANCE - Aortic valve stenosis (AS) is the most common manifestation of acquired valvular heart disease in developed countries. Several large-scale randomized clinical trials investigating the entire spectrum of patients with severe symptomatic AS from low to prohibitive risk have established transcatheter aortic valve replacement (TAVR) as a safe and effective alternative to surgical aortic valve replacement.


OBSERVATIONS - There are currently only 3 types of TAVR devices commercially available in the US, but several other valve types are undergoing clinical trials in the US. Because of fundamental differences in engineering features, each TAVR device type has specific strengths and limitations. This review aims to provide an overview of design features and clinical outcomes of various TAVR devices that are either commercially available or undergoing clinical investigation.


CONCLUSIONS AND RELEVANCE - Given the lack of large-scale head-to-head comparisons of various TAVR devices and the rapid development of new device iterations, there is insufficient evidence to claim superiority of one device type over another. Nonetheless, as each TAVR device has unique design characteristics, certain patient-related and anatomy-related factors may slightly favor one or several particular designs.