CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

A Novel Familial Cardiac Arrhythmia Syndrome with Widespread ST-Segment Depression Percutaneous coronary intervention using a combination of robotics and telecommunications by an operator in a separate physical location from the patient: an early exploration into the feasibility of telestenting (the REMOTE-PCI study) Screening for Cardiovascular Disease Risk With Electrocardiography: US Preventive Services Task Force Recommendation Statement Cardiac MRI Endpoints in Myocardial Infarction Experimental and Clinical Trials JACC Scientific Expert Panel Sudden Cardiac Arrest Survivorship: A Scientific Statement From the American Heart Association Digital learning and the future cardiologist Defining High Bleeding Risk in Patients Undergoing Percutaneous Coronary Intervention: A Consensus Document From the Academic Research Consortium for High Bleeding Risk Management of No-Reflow Phenomenon in the Catheterization Laboratory Effect of Empagliflozin on Cardiovascular and Renal Outcomes in Patients With Heart Failure by Baseline Diabetes Status - Results from the EMPEROR-Reduced Trial Plaque progression assessed by a novel semi-automated quantitative plaque software on coronary computed tomography angiography between diabetes and non-diabetes patients: A propensity-score matching study

Original ResearchOctober 7, 2020

JOURNAL:JAMA Cardiol. Article Link

Transcatheter Aortic Valve Replacement in Low-risk Patients With Bicuspid Aortic Valve Stenosis

JK Forrest, B Ramlawi, GM Deeb et al.

ABSTRACT

IMPORTANCE - The outcomes of transcatheter aortic valve replacement (TAVR) in low-risk patients with bicuspid aortic valve stenosis have not been studied in a large scale, multicentered, prospective fashion.


OBJECTIVE - To evaluate the procedural safety, efficacy, and 30-day outcomes of TAVR in patients with bicuspid aortic stenosis at low surgical risk.


DESIGN, SETTING, AND PARTICIPANTS - The Low Risk Bicuspid Study is a prospective, single-arm trial study with inclusion/exclusion criteria developed from the Evolut Low Risk Randomized Trial. Follow-up is planned for 10 years. Patients underwent TAVR at 25 centers in the United States who were also participating in the Evolut Low Risk Randomized Trial from December 2018 to October 2019. Eligible patients had severe bicuspid aortic valve stenosis and met American Heart Association/American College of Cardiology guideline indications for aortic valve replacement.

 

INTERVENTIONS - Patients underwent attempted implant of an Evolut or Evolut PRO transcatheter aortic valve, with valve size based on annular measurements.

 

MAIN OUTCOMES AND MEASURES - The prespecified primary end point was the incidence of all-cause mortality or disabling stroke at 30 days. The prespecified primary efficacy end point was device success defined as the absence of procedural mortality, the correct position of 1 bioprosthetic heart valve in the proper anatomical location, and the absence of more than mild aortic regurgitation postprocedure.

 

RESULTS - A total of 150 patients underwent an attempted implant. Baseline characteristics include mean age of 70.3 (5.5) years, 48.0% female (n = 72), and a mean Society of Thoracic Surgeons score of 1.4 (0.6%). Most patients (136; 90.7%) had Sievers type I valve morphology. The incidence of all-cause mortality or disabling stroke was 1.3% (95% CI, 0.3%-5.3%) at 30 days. The device success rate was 95.3% (95% CI, 90.5%-98.1%). At 30 days, the mean (SD) AV gradient was 7.6 (3.7) mm Hg and effective orifice area was 2.3 (0.7) cm2. A new permanent pacemaker was implanted in 22 patients (15.1%). No patients had greater than mild paravalvular leak.

 

CONCLUSIONS AND RELEVANCE - Transcatheter aortic valve replacement in lowsurgical risk patients with bicuspid aortic valve stenosis achieved favorable 30-day results, with low rates of death and stroke and high device success rate.

 

TRIAL REGISTRATION - ClinicalTrials.gov Identifier: NCT03635424