Primary Prevention of Heart Failure in Women Impact of Intravascular Ultrasound-Guided Percutaneous Coronary Intervention on Long-Term Clinical Outcomes in Patients Undergoing Complex Procedures Six Versus 12 Months of Dual Antiplatelet Therapy After Implantation of Biodegradable Polymer Sirolimus-Eluting Stent: Randomized Substudy of the I-LOVE-IT 2 Trial Catastrophic catheter-induced coronary artery vasospasm successfully rescued using intravascular ultrasound imaging guidance Atherosclerotic plaque with ultrasonic attenuation affects coronary reflow and infarct size in patients with acute coronary syndrome: an intravascular ultrasound study Effect of Intravascular Ultrasound-Guided vs Angiography-Guided Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial Type 2 Diabetes Mellitus and Heart Failure: A Scientific Statement From the American Heart Association and the Heart Failure Society of America Twelve or 30 months of dual antiplatelet therapy after drug-eluting stents Temporal Trends in Transcatheter Aortic Valve Replacement in France: FRANCE 2 to FRANCE TAVI Age-Related Characteristics and Outcomes of Patients With Heart Failure With Preserved Ejection Fraction

Original ResearchOctober 7, 2020

JOURNAL:JAMA Cardiol. Article Link

Transcatheter Aortic Valve Replacement in Low-risk Patients With Bicuspid Aortic Valve Stenosis

JK Forrest, B Ramlawi, GM Deeb et al.

ABSTRACT

IMPORTANCE - The outcomes of transcatheter aortic valve replacement (TAVR) in low-risk patients with bicuspid aortic valve stenosis have not been studied in a large scale, multicentered, prospective fashion.


OBJECTIVE - To evaluate the procedural safety, efficacy, and 30-day outcomes of TAVR in patients with bicuspid aortic stenosis at low surgical risk.


DESIGN, SETTING, AND PARTICIPANTS - The Low Risk Bicuspid Study is a prospective, single-arm trial study with inclusion/exclusion criteria developed from the Evolut Low Risk Randomized Trial. Follow-up is planned for 10 years. Patients underwent TAVR at 25 centers in the United States who were also participating in the Evolut Low Risk Randomized Trial from December 2018 to October 2019. Eligible patients had severe bicuspid aortic valve stenosis and met American Heart Association/American College of Cardiology guideline indications for aortic valve replacement.

 

INTERVENTIONS - Patients underwent attempted implant of an Evolut or Evolut PRO transcatheter aortic valve, with valve size based on annular measurements.

 

MAIN OUTCOMES AND MEASURES - The prespecified primary end point was the incidence of all-cause mortality or disabling stroke at 30 days. The prespecified primary efficacy end point was device success defined as the absence of procedural mortality, the correct position of 1 bioprosthetic heart valve in the proper anatomical location, and the absence of more than mild aortic regurgitation postprocedure.

 

RESULTS - A total of 150 patients underwent an attempted implant. Baseline characteristics include mean age of 70.3 (5.5) years, 48.0% female (n = 72), and a mean Society of Thoracic Surgeons score of 1.4 (0.6%). Most patients (136; 90.7%) had Sievers type I valve morphology. The incidence of all-cause mortality or disabling stroke was 1.3% (95% CI, 0.3%-5.3%) at 30 days. The device success rate was 95.3% (95% CI, 90.5%-98.1%). At 30 days, the mean (SD) AV gradient was 7.6 (3.7) mm Hg and effective orifice area was 2.3 (0.7) cm2. A new permanent pacemaker was implanted in 22 patients (15.1%). No patients had greater than mild paravalvular leak.

 

CONCLUSIONS AND RELEVANCE - Transcatheter aortic valve replacement in lowsurgical risk patients with bicuspid aortic valve stenosis achieved favorable 30-day results, with low rates of death and stroke and high device success rate.

 