CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Prognostic impact of atrial fibrillation in cardiogenic shock complicating acute myocardial infarction: a substudy of the IABP-SHOCK II trial Relationship Between Infarct Size and Outcomes Following Primary PCI: Patient-Level Analysis From 10 Randomized Trials Intravascular ultrasound-guided percutaneous coronary intervention in left main coronary bifurcation lesions: a review Predicting lifetime risk for developing atherosclerotic cardiovascular disease in Chinese population: the China-PAR project Prognostic impact of non-culprit chronic total occlusions in infarct-related cardiogenic shock: results of the randomised IABP-SHOCK II trial Risk of Early Adverse Events After Clopidogrel Discontinuation in Patients Undergoing Short-Term Dual Antiplatelet Therapy: An Individual Participant Data Analysis Risk Stratification for Patients in Cardiogenic Shock After Acute Myocardial Infarction Non-eligibility for reperfusion therapy in patients presenting with ST-segment elevation myocardial infarction: Contemporary insights from the National Cardiovascular Data Registry (NCDR) Intracoronary Optical Coherence Tomography 2018: Current Status and Future Directions Predicting the 10-Year Risks of Atherosclerotic Cardiovascular Disease in Chinese Population: The China-PAR Project (Prediction for ASCVD Risk in China)

Original Research2018 Jan;11(1):111-123.

JOURNAL:JACC Cardiovasc Imaging. Article Link

Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) Results From the OPINION Imaging Study

Otake H, Akasaka T, OPINION Investigators et al. Keywords: intravascular ultrasound; optical coherence tomography; optical frequency domain imaging; percutaneous coronary intervention

ABSTRACT


OBJECTIVES - The authors sought to clarify how intravascular ultrasound (IVUS) and optical coherence tomography affect percutaneous coronary intervention (PCI) with current-generation drug-eluting stents in a pre-specified substudy of the OPINION (OPtical frequency domain imaging versus INtravascular ultrasound in percutaneous coronary interventiON) trial, a multicenter, prospective, randomized, noninferiority trial comparing optical frequency domain imaging (OFDI)-guided PCI with IVUS-guided PCI.


BACKGROUND - The impact of these 2 imaging modalities in guiding PCI remains unknown.


METHODS - Of 829 patients enrolled in the OPINION trial, 106 were included in the present imaging substudy. Their PCI was guided by either IVUS or OFDI, but all patients were imaged by both modalities after PCI and by OFDI at 8 months. Angiographic, OFDI, and IVUS images were analyzed by independent core laboratories, and statistical analysis was done independently by a dedicated institution.


RESULTS -  A total of 103 patients underwent either OFDI-guided (n = 54) or IVUS-guided (n = 49) PCI. Immediately after PCI, OFDI-guided PCI was associated with a smaller trend of minimum stent area (5.28 ± 1.65 mm2 vs. 6.12 ± 2.34 mm2; p = 0.088), fewer proximal stent-edge hematomas (p = 0.04), and fewer irregular protrusions (p = 0.014) than IVUS-guided PCI. At 8 months, the neointima area tended to be smaller in the OFDI-guided PCI group than in the IVUS-guided PCI group (0.56 ± 0.30 mm2 vs. 0.80 ± 0.65 mm2; p = 0.057), although the percentage of uncovered struts was significantly higher in the OFDI-guided PCI group than in the IVUS-guided PCI group (6.97 ± 7.03% vs. 4.67 ± 6.43%; p = 0.039). The minimum lumen area was comparable in both groups (p = 0.18).


CONCLUSIONS - There were several differences in local findings between OFDI- and IVUS-guided PCI as expected given the different protocols for stent sizing in the 2 groups. The minimum lumen area at the 8-month follow-up was comparable, suggesting that OFDI- and IVUS-guided PCI are similarly feasible using the current-generation drug-eluting stents. (OPtical frequency domain imaging versus INtravascular ultrasound in percutaneous coronary interventiON; NCT01873222)


Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.