Risk of Coronary Obstruction and Feasibility of Coronary Access After Repeat Transcatheter Aortic Valve Replacement With the Self-Expanding Evolut Valve: A Computed Tomography Simulation Study Differential prognostic impact of treatment strategy among patients with left main versus non-left main bifurcation lesions undergoing percutaneous coronary intervention: results from the COBIS (Coronary Bifurcation Stenting) Registry II 2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial Mechanisms of in-stent restenosis after drug-eluting stent implantation: intravascular ultrasound analysis Effects of Icosapent Ethyl on Total Ischemic Events: From REDUCE-IT The Year in Cardiovascular Medicine 2020: Coronary Prevention: Looking back on the Year in Cardiovascular Medicine for 2020 in the field of coronary prevention is Professor Ramon Estruch, Dr Luis Ruilope, and Professor Francesco Cosentino. Mark Nicholls meets them Two-year outcomes following unprotected left main stenting with first vs new-generation drug-eluting stents: the FINE registry. EuroIntervention. Edoxaban versus Vitamin K Antagonist for Atrial Fibrillation after TAVR Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation

Clinical Case Study2020 Nov 14;ehaa817.

JOURNAL:Eur Heart J. Article Link

Chimney technique in a TAVR-in-TAVR procedure with high risk of left main artery ostium occlusion

A Dibie, Q Landolff, A Veugeois et al. Keywords: clinical case; chimney technique; TAVR-in-TAVR procedure; left main artery ostium occlusion

ABSTRACT

An 87-year-old woman was referred to our centre for a valve-in-valve transcatheter aortic valve replacement (TAVR). She underwent a TAVR procedure with implantation of a SAPIEN XT 26 mm (Edwards Lifesciences) bioprosthesis 7 years before but subsequently developed symptomatic aortic valve failure (mean gradient = 64 mmHg).

Pre-procedural computed tomography (CT) scan identified a low height between the valvular plane and left main coronary artery (LMA) ostium equal to 2.7 mm (Panel A1). Valve simulation technique was applied: the virtual transcatheter heart valve/coronary distance was measured at 4.0 mm (Panel A2). The coronary angiography revealed no recurrent stenosis (Panel B)....