CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Prevention, Diagnosis, and Management of Radiation-Associated Cardiac Disease: JACC Scientific Expert Panel Obesity, Diabetes, and Acute Coronary Syndrome: Differences Between Asians and Whites Randomized Comparison of Everolimus- and Zotarolimus-Eluting Coronary Stents With Biolimus-Eluting Stents in All-Comer Patients Complete Versus Culprit-Only Revascularization in STEMI: a Contemporary Review Coronary Catheterization and Percutaneous Coronary Intervention in China: 10-Year Results From the China PEACE-Retrospective CathPCI Study Acute Myocardial Infarction after Laboratory-Confirmed Influenza Infection Effect of Shorter Door-to-Balloon Times Over 20 Years on Outcomes of Patients With Anterior ST-Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention Prognostic significance of QRS fragmentation and correlation with infarct size in patients with anterior ST-segment elevation myocardial infarction treated with percutaneous coronary intervention: Insights from the INFUSE-AMI trial 2018 AHA/ACC/AACVPR/AAPA/ABC/ACPM/ADA/AGS/APhA/ASPC/NLA/PCNA Guideline on the Management of Blood Cholesterol: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines Relation of Stature to Outcomes in Korean Patients Undergoing Primary Percutaneous Coronary Intervention for Acute ST-Elevation Myocardial Infarction (from the INTERSTELLAR Registry)

Clinical Case Study2020 Nov 14;ehaa817.

JOURNAL:Eur Heart J. Article Link

Chimney technique in a TAVR-in-TAVR procedure with high risk of left main artery ostium occlusion

A Dibie, Q Landolff, A Veugeois et al. Keywords: clinical case; chimney technique; TAVR-in-TAVR procedure; left main artery ostium occlusion

ABSTRACT

An 87-year-old woman was referred to our centre for a valve-in-valve transcatheter aortic valve replacement (TAVR). She underwent a TAVR procedure with implantation of a SAPIEN XT 26 mm (Edwards Lifesciences) bioprosthesis 7 years before but subsequently developed symptomatic aortic valve failure (mean gradient = 64 mmHg).

Pre-procedural computed tomography (CT) scan identified a low height between the valvular plane and left main coronary artery (LMA) ostium equal to 2.7 mm (Panel A1). Valve simulation technique was applied: the virtual transcatheter heart valve/coronary distance was measured at 4.0 mm (Panel A2). The coronary angiography revealed no recurrent stenosis (Panel B)....