CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Subcutaneous Selatogrel Inhibits Platelet Aggregation in Patients With Acute Myocardial Infarction Short Sleep Duration, Obstructive Sleep Apnea, Shiftwork, and the Risk of Adverse Cardiovascular Events in Patients After an Acute Coronary Syndrome Stent Thrombosis Risk Over Time on the Basis of Clinical Presentation and Platelet Reactivity: Analysis From ADAPT-DES Restenosis, Stent Thrombosis, and Bleeding Complications - Navigating Between Scylla and Charybdis Complete Revascularization During Primary Percutaneous Coronary Intervention Reduces Death and Myocardial Infarction in Patients With Multivessel Disease-Meta-Analysis and Meta-Regression of Randomized Trials In-Hospital Coronary Revascularization Rates and Post-Discharge Mortality Risk in Non–ST-Segment Elevation Acute Coronary Syndrome Ticagrelor versus Clopidogrel in Patients with STEMI Treated with Fibrinolytic Therapy: TREAT Trial An EAPCI Expert Consensus Document on Ischaemia with Non-Obstructive Coronary Arteries in Collaboration with European Society of Cardiology Working Group on Coronary Pathophysiology & Microcirculation Endorsed by Coronary Vasomotor Disorders International Study Group The association between body mass index and obesity with survival in pulmonary arterial hypertension Chronic total occlusion intervention of the non-infarct-related artery in acute myocardial infarction patients: the Korean multicenter chronic total occlusion registry

Clinical Case Study2020 Nov 14;ehaa817.

JOURNAL:Eur Heart J. Article Link

Chimney technique in a TAVR-in-TAVR procedure with high risk of left main artery ostium occlusion

A Dibie, Q Landolff, A Veugeois et al. Keywords: clinical case; chimney technique; TAVR-in-TAVR procedure; left main artery ostium occlusion

ABSTRACT

An 87-year-old woman was referred to our centre for a valve-in-valve transcatheter aortic valve replacement (TAVR). She underwent a TAVR procedure with implantation of a SAPIEN XT 26 mm (Edwards Lifesciences) bioprosthesis 7 years before but subsequently developed symptomatic aortic valve failure (mean gradient = 64 mmHg).

Pre-procedural computed tomography (CT) scan identified a low height between the valvular plane and left main coronary artery (LMA) ostium equal to 2.7 mm (Panel A1). Valve simulation technique was applied: the virtual transcatheter heart valve/coronary distance was measured at 4.0 mm (Panel A2). The coronary angiography revealed no recurrent stenosis (Panel B)....