Anatomical plaque and vessel characteristics are associated with hemodynamic indices including fractional flow reserve and coronary flow reserve: A prospective exploratory intravascular ultrasound analysis A Novel Circulating MicroRNA for the Detection of Acute Myocarditis Nonculprit Lesion Myocardial Infarction Following Percutaneous Coronary Intervention in Patients With Acute Coronary Syndrome Diagnosis and Prognosis of Coronary Artery Disease with SPECT and PET Spontaneous Coronary Artery Dissection: JACC State-of-the-Art Review Optical coherence tomography findings: insights from the “randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chronic total occlusions” (PRISON IV) trial Canadian spontaneous coronary artery dissection cohort study: in-hospital and 30-day outcomes Prognostic Implication of Thermodilution Coronary Flow Reserve in Patients Undergoing Fractional Flow Reserve Measurement Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients How Low to Go With Glucose, Cholesterol, and Blood Pressure in Primary Prevention of CVD

Original Research2018 Jan 25. [Epub ahead of print]

JOURNAL:J Interv Cardiol. Article Link

Long-term outcomes of rotational atherectomy of underexpanded stents. A single center experience

Hernández-Enríquez M, Campelo-Parada F, Lhermusier T et al. Keywords: outcomes; rotational atherectomy; stentablation; underexpanded stents

ABSTRACT


OBJECTIVES - To analyze the procedural and long-term outcomes of the use of rotational atherectomy (RA) in underexpanded stents in our cohort and to provide an overview of currently available data on this technique.


BACKGROUND - Stent underexpansion (SU) has been related to stent thrombosis and restenosis. RA has been used to treat undilatable SU as a bail-out strategy with encouraging results.


METHODS - This is an observational, single-center study. We included patients who underwent stentablation between 2013 and 2017. Baseline demographics, procedural results, in-hospital major adverse cardiac events (MACE), and long-term follow-up MACE were retrospectively collected.


RESULTS - A total of 11 patients (90.9% males, mean age 65.4 ± 18.6) were included in this study. Median left ventricle ejection fraction was 53.5% [46.2-55]. Median calculated Syntax score was 16 [9-31] and 45.5% of patients were admitted for acute coronary syndrome. Radial approach was used in 63.6% of cases. Most patients only required one burr (45% used a 1.5 mm diameter burr) during the intervention. Procedural success was achieved in 90.9% of the cases. Acute lumen gain was 42.7% [30.7-61.49]. There were no in-hospital deaths or MACE. At a median follow-up of 26 months, only one patient (9.1%) suffered MACE in the context of acute coronary syndrome, and two patients (18.2%) required non-target lesion revascularization. No deaths were reported.


CONCLUSIONS - RA of under expanded stents is a feasible option with a high rate of procedural success. At long-term follow-up, all of them were alive and 90.9% of patients remained free from MACE.


© 2018 The Authors. Journal of Interventional Cardiology Published by Wiley Periodicals, Inc.