CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Assessment of coronary atherosclerosis by IVUS and IVUS-based imaging modalities: progression and regression studies, tissue composition and beyond Frailty Is Intertwined With Heart Failure: Mechanisms, Prevalence, Prognosis, Assessment, and Management Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis Phenomapping for Novel Classification of Heart Failure With Preserved Ejection Fraction Surgery Does Not Improve Survival in Patients With Isolated Severe Tricuspid Regurgitation Temporal Trends in Inpatient Use of Intravascular Imaging Among Patients Undergoing Percutaneous Coronary Intervention in the United States Derivation, Validation, and Prognostic Utility of a Prediction Rule for Nonresponse to Clopidogrel: The ABCD-GENE Score Positive recommendation for angiotensin receptor/neprilysin inhibitor: First medication approval for heart failure without "reduced ejection fraction" 6-Month Versus 12-Month Dual-Antiplatelet Therapy Following Long Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial Safety of six-month dual antiplatelet therapy after second-generation drug-eluting stent implantation: OPTIMA-C Randomised Clinical Trial and OCT Substudy

Clinical Case Study2018 Jan 1;19(1):116.

JOURNAL:Eur Heart J Cardiovasc Imaging. Article Link

In vivo comparison of lipid-rich plaque on near-infrared spectroscopy with histopathological analysis of coronary atherectomy specimens

Nishihira K, Asaumi Y, Kataoka Y et al. Keywords: atherectomy, coronary spectroscopy, near-infrared lipids

ABSTRACT


A 42-year-old man with angina pectoris was hospitalized to undergo percutaneous coronary intervention (PCI) for a significant stenosis in the mid-left anterior descending (LAD) coronary artery (Panel A). Optical coherence tomography (OCT) and near-infrared spectroscopy (NIRS) imaging at the arrowhead site identified the presence of lipid-rich plaque, exhibiting a high maximum 4-mm lipid core burden index (max-LCBI) with the value of 925 (Panels B and C; Supplementary data online, Video S1). Following PCI with directional coronary atherectomy (DCA), resection of the lipid-rich plaque was observed on OCT imaging (Panels D and D’; Supplementary data online, Video S2). Corresponding NIRS imaging demonstrated a marked reduction of yellow signals on chemogram accompanied by decrease in max-LCBI to 248 (Panel E,asterisk).