CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Stress Echocardiography and PH: What Do the Findings Mean? Serial intravascular ultrasound analysis of the main and side branches in bifurcation lesions treated with the T-stenting technique Extracellular Myocardial Volume in Patients With Aortic Stenosis Infective endocarditis after transcatheter aortic valve implantation: a nationwide study Treatment and prevention of lipoprotein(a)-mediated cardiovascular disease: the emerging potential of RNA interference therapeutics 2019 AHA/ACC Clinical Performance and Quality Measures for Adults With High Blood Pressure: A Report of the American College of Cardiology/American Heart Association Task Force on Performance Measures Safety and efficacy of the bioabsorbable polymer everolimus-eluting stent versus durable polymer drug-eluting stents in high-risk patients undergoing PCI: TWILIGHT-SYNERGY Leaflet immobility and thrombosis in transcatheter aortic valve replacement New-onset atrial fibrillation after PCI and CABG for left main disease: insights from the EXCEL trial and additional studies Dual Antiplatelet TherapyIs It Time to Cut the Cord With Aspirin?

Original Research2021 Feb 2;S1936-8798(20)32281-0.

JOURNAL:JACC Cardiovasc Interv. Article Link

Online Quantitative Aortographic Assessment of Aortic Regurgitation After TAVR: Results of the OVAL Study

R Modolo, M van Mourik, PW Serruys et al. Keywords: TAVR; aortic regurgitation; paravalvular leak

ABSTRACT

BACKGROUND - Quantitative assessment of regurgitation after TAVR through aortography using videodensitometry is simple, reproducible, and validated in vitro, in vivo, in clinical trials, and in real-worldpatients. However, thus far the assessment has been done offline.

 

METHODS - This was a single center, prospective, proof-of-principle, feasibility study. One hundred consecutive patients with aortic stenosis and indications to undergo TAVR were enrolled. All final aortograms were analyzed immediately after acquisition in the catheterization laboratory and were also sent to an independent core laboratory for blinded offline assessment. The primary endpoint of the study was the feasibility of the online assessment of regurgitation (percentage of analyzable cases). The secondary endpoint was the reproducibility of results between the online assessment and the offline analysis by the core laboratory.

 

RESULTS - Patientsmean age was 81 ± 7 years, and 56% were men. The implanted valves were either SAPIEN 3 (97%) or SAPIEN 3 Ultra (3%). The primary endpoint of online feasibility of analysis was 92% (95% confidence interval [CI]: 86% to 97%) which was the same feasibility encountered by the core laboratory (92%; 95% CI: 86% to 97%). Reproducibility assessment showed a high correlation between online and core laboratory evaluations (R2 = 0.87, p < 0.001), with an intraclass correlation coefficient of 0.962 (95% CI: 0.942 to 0.975; p < 0.001).

 

CONCLUSIONS - This study showed high feasibility of online quantitative assessment of regurgitation and high agreement between the online examiner and core laboratory. These results may pave the way for the application of videodensitometry in the catheterization laboratory after TAVR. (Online Videodensitometric Assessment of Aortic Regurgitation in the Cath-Lab [OVAL]; NCT04047082)