CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Temporal Trends in Inpatient Use of Intravascular Imaging Among Patients Undergoing Percutaneous Coronary Intervention in the United States First-in-man evaluation of intravascular optical frequency domain imaging (OFDI) of Terumo: a comparison with intravascular ultrasound and quantitative coronary angiography Therapeutic Options for In-Stent Restenosis Derivation, Validation, and Prognostic Utility of a Prediction Rule for Nonresponse to Clopidogrel: The ABCD-GENE Score A Randomized Study of Distal Filter Protection Versus Conventional Treatment During Percutaneous Coronary Intervention in Patients With Attenuated Plaque Identified by Intravascular Ultrasound The pyruvate-lactate axis modulates cardiac hypertrophy and heart failure Second-generation drug-eluting stent implantation followed by 6- versus 12-month dual antiplatelet therapy: the SECURITY randomized clinical trial Safety of six-month dual antiplatelet therapy after second-generation drug-eluting stent implantation: OPTIMA-C Randomised Clinical Trial and OCT Substudy Mechanical circulatory support devices in advanced heart failure: 2020 and beyond 6-Month Versus 12-Month Dual-Antiplatelet Therapy Following Long Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial

Original Research2021 Feb 2;S1936-8798(20)32281-0.

JOURNAL:JACC Cardiovasc Interv. Article Link

Online Quantitative Aortographic Assessment of Aortic Regurgitation After TAVR: Results of the OVAL Study

R Modolo, M van Mourik, PW Serruys et al. Keywords: TAVR; aortic regurgitation; paravalvular leak

ABSTRACT

BACKGROUND - Quantitative assessment of regurgitation after TAVR through aortography using videodensitometry is simple, reproducible, and validated in vitro, in vivo, in clinical trials, and in real-worldpatients. However, thus far the assessment has been done offline.

 

METHODS - This was a single center, prospective, proof-of-principle, feasibility study. One hundred consecutive patients with aortic stenosis and indications to undergo TAVR were enrolled. All final aortograms were analyzed immediately after acquisition in the catheterization laboratory and were also sent to an independent core laboratory for blinded offline assessment. The primary endpoint of the study was the feasibility of the online assessment of regurgitation (percentage of analyzable cases). The secondary endpoint was the reproducibility of results between the online assessment and the offline analysis by the core laboratory.

 

RESULTS - Patientsmean age was 81 ± 7 years, and 56% were men. The implanted valves were either SAPIEN 3 (97%) or SAPIEN 3 Ultra (3%). The primary endpoint of online feasibility of analysis was 92% (95% confidence interval [CI]: 86% to 97%) which was the same feasibility encountered by the core laboratory (92%; 95% CI: 86% to 97%). Reproducibility assessment showed a high correlation between online and core laboratory evaluations (R2 = 0.87, p < 0.001), with an intraclass correlation coefficient of 0.962 (95% CI: 0.942 to 0.975; p < 0.001).

 

CONCLUSIONS - This study showed high feasibility of online quantitative assessment of regurgitation and high agreement between the online examiner and core laboratory. These results may pave the way for the application of videodensitometry in the catheterization laboratory after TAVR. (Online Videodensitometric Assessment of Aortic Regurgitation in the Cath-Lab [OVAL]; NCT04047082)