4-Step Protocol for Disparities in STEMI Care and Outcomes in Women Comparison of Stenting Versus Bypass Surgery According to the Completeness of Revascularization in Severe Coronary Artery Disease: Patient-Level Pooled Analysis of the SYNTAX, PRECOMBAT, and BEST Trials Long-Term Outcomes of Patients With Late Presentation of ST-Segment Elevation Myocardial Infarction Triage Considerations for Patients Referred for Structural Heart Disease Intervention During the Coronavirus Disease 2019 (COVID-19) Pandemic: An ACC /SCAI Consensus Statement Galectin-3 Levels and Outcomes After Myocardial Infarction: A Population-Based Study Early Natural History of Spontaneous Coronary Artery Dissection Prevalence of Coronary Vasospasm Using Coronary Reactivity Testing in Patients With Spontaneous Coronary Artery Dissection Effect of Pre-Hospital Crushed Prasugrel Tablets in Patients with STEMI Planned for Primary Percutaneous Coronary Intervention: The Randomized COMPARE CRUSH Trial Clinical Practice Guideline for Screening and Management of High Blood Pressure in Children and Adolescents Radial versus femoral access and bivalirudin versus unfractionated heparin in invasively managed patients with acute coronary syndrome (MATRIX): final 1-year results of a multicentre, randomised controlled trial

Clinical Trial2022 Mar 8;79(9):882-896.

JOURNAL:J Am Coll Cardiol. Article Link

2-Year Outcomes After Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients

JK Forrest, GM Deeb, SJ Yakubov et al. Keywords: TAVR; aortic stenosis; low surgical risk; self-expanding supra-annular valve

ABSTRACT

BACKGROUND - The Evolut Low Risk Trial (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients) showed that transcatheter aortic valve replacement (TAVR) with a supra-annular, self-expanding valve was noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke at 2 years. This finding was based on a Bayesian analysis performed after 850 patients had reached 1 year of follow-up.

 

OBJECTIVES - The goal of this study was to report the full 2-year clinical and echocardiographic outcomes for patients enrolled in the Evolut Low Risk Trial.

 

METHODS - A total of 1,414 low-surgical risk patients with severe aortic stenosis were randomized to receive TAVR or surgical AVR. An independent clinical events committee adjudicated adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints.

 

RESULTS - An attempted implant was performed in 730 TAVR and 684 surgical patients from March 2016 to May 2019. The Kaplan-Meier rates for the complete 2-year primary endpoint of death or disabling stroke were 4.3% in the TAVR group and 6.3% in the surgery group (P = 0.084). These rates were comparable to the interim Bayesian rates of 5.3% with TAVR and 6.7% with surgery (difference -  -1.4%; 95% Bayesian credible interval: -4.9% to 2.1%). All-cause mortality rates were 3.5% vs 4.4% (P = 0.366), and disabling stroke rates were 1.5% vs 2.7% (P = 0.119), respectively. Between years 1 and 2, there was no convergence of the primary outcome curves.

 

CONCLUSIONS - The complete 2-year follow-up from the Evolut Low Risk Trial found that TAVR is noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke, with event rates that were slightly better than those predicted by using the Bayesian analysis. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients [Evolut Low Risk Trial]; NCT02701283).