CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

The Wait for High-Sensitivity Troponin Is Over—Proceed Cautiously Impact of the US Food and Drug Administration–Approved Sex-Specific Cutoff Values for High-Sensitivity Cardiac Troponin T to Diagnose Myocardial Infarction Clinical Outcomes Following Intravascular Imaging-Guided Versus Coronary Angiography–Guided Percutaneous Coronary Intervention With Stent Implantation: A Systematic Review and Bayesian Network Meta-Analysis of 31 Studies and 17,882 Patients Good response to tolvaptan shortens hospitalization in patients with congestive heart failure Revision: prognostic impact of baseline glucose levels in acute myocardial infarction complicated by cardiogenic shock-a substudy of the IABP-SHOCK II-trial Usefulness of longitudinal reconstructed optical coherence tomography images for predicting the need for the reverse wire technique during coronary bifurcation interventions Cardiac Implantable Electronic Devices in Patients With Left Ventricular Assist Systems Wearable Cardioverter-Defibrillator after Myocardial Infarction Use of Risk Assessment Tools to Guide Decision-Making in the Primary Prevention of Atherosclerotic Cardiovascular Disease A Special Report From the American Heart Association and American College of Cardiology What's new in the Fourth Universal Definition of Myocardial infarction?

Clinical Trial2022 Mar 8;79(9):882-896.

JOURNAL:J Am Coll Cardiol. Article Link

2-Year Outcomes After Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients

JK Forrest, GM Deeb, SJ Yakubov et al. Keywords: TAVR; aortic stenosis; low surgical risk; self-expanding supra-annular valve

ABSTRACT

BACKGROUND - The Evolut Low Risk Trial (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients) showed that transcatheter aortic valve replacement (TAVR) with a supra-annular, self-expanding valve was noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke at 2 years. This finding was based on a Bayesian analysis performed after 850 patients had reached 1 year of follow-up.

 

OBJECTIVES - The goal of this study was to report the full 2-year clinical and echocardiographic outcomes for patients enrolled in the Evolut Low Risk Trial.

 

METHODS - A total of 1,414 low-surgical risk patients with severe aortic stenosis were randomized to receive TAVR or surgical AVR. An independent clinical events committee adjudicated adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints.

 

RESULTS - An attempted implant was performed in 730 TAVR and 684 surgical patients from March 2016 to May 2019. The Kaplan-Meier rates for the complete 2-year primary endpoint of death or disabling stroke were 4.3% in the TAVR group and 6.3% in the surgery group (P = 0.084). These rates were comparable to the interim Bayesian rates of 5.3% with TAVR and 6.7% with surgery (difference -  -1.4%; 95% Bayesian credible interval: -4.9% to 2.1%). All-cause mortality rates were 3.5% vs 4.4% (P = 0.366), and disabling stroke rates were 1.5% vs 2.7% (P = 0.119), respectively. Between years 1 and 2, there was no convergence of the primary outcome curves.

 

CONCLUSIONS - The complete 2-year follow-up from the Evolut Low Risk Trial found that TAVR is noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke, with event rates that were slightly better than those predicted by using the Bayesian analysis. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients [Evolut Low Risk Trial]; NCT02701283).