CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Decline in Left Ventricular Ejection Fraction During Follow-Up in Patients With Severe Aortic Stenosis Myocardial bridging of the left anterior descending coronary artery is associated with reduced myocardial perfusion reserve: a 13N-ammonia PET study Transcatheter Aortic Valve Replacement: Role of Multimodality Imaging in Common and Complex Clinical Scenarios Short Length of Stay After Elective Transfemoral Transcatheter Aortic Valve Replacement Is Not Associated With Increased Early or Late Readmission Risk Left Ventricular Hypertrophy and Clinical Outcomes Over 5 Years After TAVR: An Analysis of the PARTNER Trials and Registries Relationship Between Hospital Surgical Aortic Valve Replacement Volume and Transcatheter Aortic Valve Replacement Outcomes Ascending Aortic Length and Risk of Aortic Adverse Events: The Neglected Dimension Contemporary Presentation and Management of Valvular Heart Disease: The EURObservational Research Programme Valvular Heart Disease II Survey Association of Coronary Artery Calcium With Long-term, Cause-Specific Mortality Among Young Adults Non-invasive detection of coronary inflammation using computed tomography and prediction of residual cardiovascular risk (the CRISP CT study): a post-hoc analysis of prospective outcome data

Original ResearchApr 03, 2022

JOURNAL:JACC Clin Electrophysiol Article Link

Clinical Impact of Residual Leaks Following Left Atrial Appendage Occlusion: Insights From the NCDR LAAO Registry

M Alkhouli, CA Du , A Killu et al.

ABSTRACT

BACKGROUND - Data on the impact of residual peri-device leak after left atrial appendage occlusion (LAAO) are limited.

 

OBJECTIVES - The goal of this study was to explore the association of peri-device leak with adverse clinical events.

 

METHODS - The National Cardiovascular Data Registry LAAO Registry was queried to identify patients undergoing LAAO between January 1, 2016, and December 31, 2019. Patients were classified according to leak size on echocardiography at 45 ± 14 days (0 mm, no leak; >0-5 mm, small leak; and >5 mm, large leak).

 

RESULTS - A total of 51,333 patients were included, of whom 37,696 (73.4%) had no leak, 13,258 (25.8%) had small leaks, and 379 (0.7%) had large leaks. The proportion of patients on warfarin at 45 days was higher in the large vs small or no leak cohorts (44.9% vs 34.4% and 32.4%, respectively; P < 0.001). At 6 and 12 months, anticoagulant utilization decreased but remained more frequent in patients with large leaks. Thromboembolic and bleeding events were uncommon in all groups. However, compared with patients with no leak, those with small leaks had slightly higher odds of stroke/transient ischemic attack/systemic embolization (adjusted HR: 1.152; 95% CI: 1.025-1.294), major bleeding (HR: 1.11; 95% CI: 1.029-1.120), and any major adverse events (HR: 1.102; 95% CI: 1.048-1.160). There were no significant differences in adverse events between patients with large leaks and patients with small or no leaks.

 

CONCLUSIONS - Small (>0-5 mm) leaks after LAAO were associated with a modestly higher incidence of thromboembolic and bleeding events; large leaks (>5 mm) were not associated with adverse events, although higher proportions of these patients were maintained on anticoagulation. Newer devices with improved seal might mitigate the events associated with residual leaks.