CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Revascularization of left main coronary artery 2020 Expert Consensus Decision Pathway on Novel Therapies for Cardiovascular Risk Reduction in Patients With Type 2 Diabetes Assessment of Vascular Dysfunction in Patients Without Obstructive Coronary Artery Disease: Why, How, and When 'Ticagrelor alone vs. dual antiplatelet therapy from 1 month after drug-eluting coronary stenting among patients with STEMI': a post hoc analysis of the randomized GLOBAL LEADERS trial 2010 ACCF/AHA guideline for assessment of cardiovascular risk in asymptomatic adults: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines Trial Design Principles for Patients at High Bleeding Risk Undergoing PCI: JACC Scientific Expert Panel SR-B1 Drives Endothelial Cell LDL Transcytosis via DOCK4 to Promote Atherosclerosis Ticagrelor Monotherapy Versus Ticagrelor With Aspirin in Patients With ST-Segment Elevation Myocardial Infarction Randomized Comparison Between Everolimus-Eluting Bioresorbable Scaffold and Metallic Stent: Multimodality Imaging Through 3 Years Hypertension: Do Inflammation and Immunity Hold the Key to Solving this Epidemic?

Original ResearchApr 03, 2022

JOURNAL:JACC Clin Electrophysiol Article Link

Clinical Impact of Residual Leaks Following Left Atrial Appendage Occlusion: Insights From the NCDR LAAO Registry

M Alkhouli, CA Du , A Killu et al.

ABSTRACT

BACKGROUND - Data on the impact of residual peri-device leak after left atrial appendage occlusion (LAAO) are limited.

 

OBJECTIVES - The goal of this study was to explore the association of peri-device leak with adverse clinical events.

 

METHODS - The National Cardiovascular Data Registry LAAO Registry was queried to identify patients undergoing LAAO between January 1, 2016, and December 31, 2019. Patients were classified according to leak size on echocardiography at 45 ± 14 days (0 mm, no leak; >0-5 mm, small leak; and >5 mm, large leak).

 

RESULTS - A total of 51,333 patients were included, of whom 37,696 (73.4%) had no leak, 13,258 (25.8%) had small leaks, and 379 (0.7%) had large leaks. The proportion of patients on warfarin at 45 days was higher in the large vs small or no leak cohorts (44.9% vs 34.4% and 32.4%, respectively; P < 0.001). At 6 and 12 months, anticoagulant utilization decreased but remained more frequent in patients with large leaks. Thromboembolic and bleeding events were uncommon in all groups. However, compared with patients with no leak, those with small leaks had slightly higher odds of stroke/transient ischemic attack/systemic embolization (adjusted HR: 1.152; 95% CI: 1.025-1.294), major bleeding (HR: 1.11; 95% CI: 1.029-1.120), and any major adverse events (HR: 1.102; 95% CI: 1.048-1.160). There were no significant differences in adverse events between patients with large leaks and patients with small or no leaks.

 

CONCLUSIONS - Small (>0-5 mm) leaks after LAAO were associated with a modestly higher incidence of thromboembolic and bleeding events; large leaks (>5 mm) were not associated with adverse events, although higher proportions of these patients were maintained on anticoagulation. Newer devices with improved seal might mitigate the events associated with residual leaks.