2019 ACC/AHA/ASE Advanced Training Statement on Echocardiography (Revision of the 2003 ACC/AHA Clinical Competence Statement on Echocardiography): A Report of the ACC Competency Management Committee Regional Heterogeneity in the Coronary Vascular Response in Women With Chest Pain and Nonobstructive Coronary Artery Disease Heart Failure With Improved Ejection Fraction-Is it Possible to Escape One’s Past? Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial Effect of Evolocumab on Complex Coronary Disease Requiring Revascularization Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Minimalist transcatheter aortic valve replacement: The new standard for surgeons and cardiologists using transfemoral access? Poor Long-Term Survival in Patients With Moderate Aortic Stenosis Transcatheter Aortic Valve Replacement in Low-risk Patients With Bicuspid Aortic Valve Stenosis Aspirin with or without Clopidogrel after Transcatheter Aortic-Valve Implantation

Clinical Trial2024 Jul 20;404(10449):245-255.

JOURNAL:Lancet. Article Link

Lowering systolic blood pressure to less than 120 mm Hg versus less than 140 mm Hg in patients with high cardiovascular risk with and without diabetes or previous stroke: an open-label,blinded-outcome,randomised trial

JM Liu, Y Li; ESPRIT Collaborative Group. Keywords: hypertension control; ASCVD prevention

ABSTRCT

BACKGROUND -  Uncertainty exists about whether lowering systolic blood pressure to less than 120 mm Hg is superior to that of less than 140 mm Hg, particularly in patients with diabetes and patients with previous stroke.

METHODS - In this open-label, blinded-outcome, randomised controlled trial, participants with high cardiovascular risk were enrolled from 116 hospitals or communities in China. We used minimised randomisation to assign participants to intensive treatment targeting standard office systolic blood pressure of less than 120 mm Hg or standard treatment targeting less than 140 mm Hg. The primary outcome was a composite of myocardial infarction, revascularisation, hospitalisation for heart failure, stroke, or death from cardiovascular causes, assessed by the intention-to-treat principle. This trial was registered with ClinicalTrials.gov, NCT04030234.


FINDINGS - Between Sept 17, 2019, and July 13, 2020, 11 255 participants (4359 with diabetes and 3022 with previous stroke) were assigned to intensive treatment (n=5624) or standard treatment (n=5631). Their mean age was 64·6 years (SD 7·1). The mean systolic blood pressure throughout the follow-up (except the first 3 months of titration) was 119·1 mm Hg (SD 11·1) in the intensive treatment group and 134·8 mm Hg (10·5) in the standard treatment group. During a median of 3·4 years of follow-up, the primary outcome event occurred in 547 (9·7%) participants in the intensive treatment group and 623 (11·1%) in the standard treatment group (hazard ratio [HR] 0·88, 95% CI 0·78-0·99; p=0·028). There was no heterogeneity of effects by diabetes status, duration of diabetes, or history of stroke. Serious adverse events of syncope occurred more frequently in the intensive treatment group (24 [0·4%] of 5624) than in standard treatment group (eight [0·1%] of 5631; HR 3·00, 95% CI 1·35-6·68). There was no significant between-group difference in the serious adverse events of hypotension, electrolyte abnormality, injurious fall, or acute kidney injury.


INTERPRETATION - For hypertensive patients at high cardiovascular risk, regardless of the status of diabetes or history of stroke, the treatment strategy of targeting systolic blood pressure of less than 120 mm Hg, as compared with that of less than 140 mm Hg, prevents major vascular events, with minor excess risk.


FUNDING -The Ministry of Science and Technology of China and Fuwai Hospital.


TRANSLATION - For the Mandarin translation of the abstract see Supplementary Materials section.