CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Another Nail in the Coffin for Intra-Aortic Balloon Counterpulsion in Acute Myocardial Infarction With Cardiogenic Shock Invasive Management of Acute Myocardial Infarction Complicated by Cardiogenic Shock: A Scientific Statement From the American Heart Association Appropriate Use Criteria and Health Status Outcomes Following Chronic Total Occlusion Percutaneous Coronary Intervention: Insights From the OPEN-CTO Registry Genetic dysregulation of endothelin-1 is implicated in coronary microvascular dysfunction Outcome of Applying the ESC 0/1-hour Algorithm in Patients With Suspected Myocardial Infarction Long-term outcomes after myocardial infarction in middle-aged and older patients with congenital heart disease-a nationwide study Mechanisms and diagnostic evaluation of persistent or recurrent angina following percutaneous coronary revascularization A Test in Context: E/A and E/e' to Assess Diastolic Dysfunction and LV Filling Pressure Invasive Versus Medical Management in Patients With Prior Coronary Artery Bypass Surgery With a Non-ST Segment Elevation Acute Coronary Syndrome: A Pilot Randomized Controlled Trial Association of Body Mass Index With Lifetime Risk of Cardiovascular Disease and Compression of Morbidity

Clinical Trial2025 Nov 24;18(22):2701-2710.

JOURNAL:JACC Cardiovasc Interv . Article Link

Paclitaxel-Coated Balloon for the Treatment of Small Vessel In-Stent Restenosis: A Subgroup Analysis of the AGENT IDE Randomized Trial

J Wen, S Dohad, R Shlofmitz et al. Keywords: drug-coated balloon; in-stent restenosis; small vessel; target lesion failure; target lesion revascularization; uncoated balloon.

Abstract

BACKGROUD -  Treatment of small vessel (SV) coronary artery disease is associated with higher restenosis rates. Drug-coated balloons offer a promising treatment option for stent failure by delivering an antiproliferative drug and avoiding an additional metal implant. However, evidence supporting the use of paclitaxel-coated balloons (PCBs) for in-stent restenosis (ISR) in SVs is limited.


OBJECTIVES - The aim of this study was to evaluate the efficacy and safety of PCB vs uncoated balloon angioplasty according to vessel size.


METHODS - AGENT IDE (A Clinical Trial to Assess the Agent Paclitaxel Coated PTCA Balloon Catheter for the Treatment of Subjects With In-Stent Restenosis) randomized 600 patients with ISR to treatment with PCBs or uncoated balloons (2:1). This prespecified analysis evaluated the treatment effect of PCBs in SV (reference vessel diameter [RVD] ≤2.75 mm) and large vessel (RVD >2.75 mm) ISR. The primary endpoint of 1-year target lesion failure (TLF) was a composite of target lesion revascularization, cardiac death, and target vessel-related myocardial infarction.


RESULTS -  Among 597 patients with known angiographic core laboratory-adjudicated vessel size, 56% had SVs (mean RVD 2.4 ± 0.3 mm) and 44% had large vessels (mean RVD 3.1 ± 0.3 mm). One-year TLF was 20.6% vs 22.6% in the SV vs large vessel groups, respectively (HR: 0.92; 95% CI: 0.65-1.31; P = 0.65). PCBs were associated with a 39% relative reduction in TLF compared with balloon angioplasty in patients with SVs (17.7% vs 27.4%; HR: 0.61; 95% CI: 0.37-0.99) and a 43% reduction in patients with large vessels (18.4% vs 30.5%; HR: 0.57; 95% CI: 0.34-0.96). The benefits of PCB use remained consistent, irrespective of vessel size (Pinteraction = 0.88). None of the patients treated with PCBs experienced definite or probable stent thrombosis.


CONCLUSIONS -  This prespecified subgroup analysis demonstrates that angioplasty with a PCB was associated with consistently reduced rates of 1-year TLF compared with an uncoated balloon in both SV and large vessel ISR patients. (A Clinical Trial to Assess the Agent Paclitaxel Coated PTCA Balloon Catheter for the Treatment of Subjects With In-Stent Restenosis [AGENT IDE]; NCT04647253).


Copyright © 2025 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.