CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Routinely reported ejection fraction and mortality in clinical practice: where does the nadir of risk lie? Association between urinary dickkopf-3, acute kidney injury, and subsequent loss of kidney function in patients undergoing cardiac surgery: an observational cohort study Derivation and Validation of a Chronic Total Coronary Occlusion Intervention Procedural Success Score From the 20,000-Patient EuroCTO Registry:The EuroCTO (CASTLE) Score Microthrombi As A Major Cause of Cardiac Injury in COVID-19: A Pathologic Study Major infections after bypass surgery and stenting for multivessel coronary disease in the randomised SYNTAX trial Optimal Stenting Technique for Complex Coronary Lesions Intracoronary Imaging-Guided Pre-Dilation, Stent Sizing, and Post-Dilation Treatment of higher-risk patients with an indication for revascularization: evolution within the field of contemporary percutaneous coronary intervention ACCF/SCAI/STS/AATS/AHA/ASNC 2009 Appropriateness Criteria for Coronary Revascularization: A Report by the American College of Cardiology Foundation Appropriateness Criteria Task Force, Society for Cardiovascular Angiography and Interventions, Society of Thoracic Surgeons, American Association for Thoracic Surgery, American Heart Association, and the American Society of Nuclear Cardiology Endorsed by the American Society of Echocardiography, the Heart Failure Society of America, and the Society of Cardiovascular Computed Tomography 2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society Dabigatran dual therapy with ticagrelor or clopidogrel after percutaneous coronary intervention in atrial fibrillation patients with or without acute coronary syndrome: a subgroup analysis from the RE-DUAL PCI trial

Clinical Trial2025 Nov 24;18(22):2701-2710.

JOURNAL:JACC Cardiovasc Interv . Article Link

Paclitaxel-Coated Balloon for the Treatment of Small Vessel In-Stent Restenosis: A Subgroup Analysis of the AGENT IDE Randomized Trial

J Wen, S Dohad, R Shlofmitz et al. Keywords: drug-coated balloon; in-stent restenosis; small vessel; target lesion failure; target lesion revascularization; uncoated balloon.

Abstract

BACKGROUD -  Treatment of small vessel (SV) coronary artery disease is associated with higher restenosis rates. Drug-coated balloons offer a promising treatment option for stent failure by delivering an antiproliferative drug and avoiding an additional metal implant. However, evidence supporting the use of paclitaxel-coated balloons (PCBs) for in-stent restenosis (ISR) in SVs is limited.


OBJECTIVES - The aim of this study was to evaluate the efficacy and safety of PCB vs uncoated balloon angioplasty according to vessel size.


METHODS - AGENT IDE (A Clinical Trial to Assess the Agent Paclitaxel Coated PTCA Balloon Catheter for the Treatment of Subjects With In-Stent Restenosis) randomized 600 patients with ISR to treatment with PCBs or uncoated balloons (2:1). This prespecified analysis evaluated the treatment effect of PCBs in SV (reference vessel diameter [RVD] ≤2.75 mm) and large vessel (RVD >2.75 mm) ISR. The primary endpoint of 1-year target lesion failure (TLF) was a composite of target lesion revascularization, cardiac death, and target vessel-related myocardial infarction.


RESULTS -  Among 597 patients with known angiographic core laboratory-adjudicated vessel size, 56% had SVs (mean RVD 2.4 ± 0.3 mm) and 44% had large vessels (mean RVD 3.1 ± 0.3 mm). One-year TLF was 20.6% vs 22.6% in the SV vs large vessel groups, respectively (HR: 0.92; 95% CI: 0.65-1.31; P = 0.65). PCBs were associated with a 39% relative reduction in TLF compared with balloon angioplasty in patients with SVs (17.7% vs 27.4%; HR: 0.61; 95% CI: 0.37-0.99) and a 43% reduction in patients with large vessels (18.4% vs 30.5%; HR: 0.57; 95% CI: 0.34-0.96). The benefits of PCB use remained consistent, irrespective of vessel size (Pinteraction = 0.88). None of the patients treated with PCBs experienced definite or probable stent thrombosis.


CONCLUSIONS -  This prespecified subgroup analysis demonstrates that angioplasty with a PCB was associated with consistently reduced rates of 1-year TLF compared with an uncoated balloon in both SV and large vessel ISR patients. (A Clinical Trial to Assess the Agent Paclitaxel Coated PTCA Balloon Catheter for the Treatment of Subjects With In-Stent Restenosis [AGENT IDE]; NCT04647253).


Copyright © 2025 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.