CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Atherosclerotic plaque with ultrasonic attenuation affects coronary reflow and infarct size in patients with acute coronary syndrome: an intravascular ultrasound study Temporal Trends in Transcatheter Aortic Valve Replacement in France: FRANCE 2 to FRANCE TAVI Impact of intravascular ultrasound on the long-term clinical outcomes in the treatment of coronary ostial lesions When and how to use SGLT2 inhibitors in patients with HFrEF or chronic kidney disease How to diagnose heart failure with preserved ejection fraction: the HFA–PEFF diagnostic algorithm: a consensus recommendation from the Heart Failure Association (HFA) of the European Society of Cardiology (ESC) Novel predictor of target vessel revascularization after coronary stent implantation: Intraluminal intensity of blood speckle on intravascular ultrasound The relationship between attenuated plaque identified by intravascular ultrasound and no-reflow after stenting in acute myocardial infarction: the HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) trial Heart Failure Outcomes With Volume-Guided Management Bridging the Gap Between Epigenetic and Genetic in PAH Intravascular Ultrasound to Guide Left Main Stem Intervention: A Sub-Study of the NOBLE Trial

Clinical Trial2017 Aug 28. [Epub ahead of print]

JOURNAL:N Engl J Med. Article Link

Oxygen Therapy in Suspected Acute Myocardial Infarction

Hofmann R, James SK, Jernberg T et al. Keywords: Oxygen Therapy; Acute Myocardial Infarction

ABSTRACT

Background - The clinical effect of routine oxygen therapy in patients with suspected acute myocardial infarction who do not have hypoxemia at baseline is uncertain.


Methods - In this registry-based randomized clinical trial, we used nationwide Swedish registries for patient enrollment and data collection. Patients with suspected myocardial infarction and an oxygen saturation of 90% or higher were randomly assigned to receive either supplemental oxygen (6 liters per minute for 6 to 12 hours, delivered through an open face mask) or ambient air.


Results - A total of 6629 patients were enrolled. The median duration of oxygen therapy was 11.6 hours, and the median oxygen saturation at the end of the treatment period was 99% among patients assigned to oxygen and 97% among patients assigned to ambient air. Hypoxemia developed in 62 patients (1.9%) in the oxygen group, as compared with 254 patients (7.7%) in the ambient-air group. The median of the highest troponin level during hospitalization was 946.5 ng per liter in the oxygen group and 983.0 ng per liter in the ambient-air group. The primary end point of death from any cause within 1 year after randomization occurred in 5.0% of patients (166 of 3311) assigned to oxygen and in 5.1% of patients (168 of 3318) assigned to ambient air (hazard ratio, 0.97; 95% confidence interval [CI], 0.79 to 1.21; P=0.80). Rehospitalization with myocardial infarction within 1 year occurred in 126 patients (3.8%) assigned to oxygen and in 111 patients (3.3%) assigned to ambient air (hazard ratio, 1.13; 95% CI, 0.88 to 1.46; P=0.33). The results were consistent across all predefined subgroups.


Conclusions - Routine use of supplemental oxygen in patients with suspected myocardial infarction who did not have hypoxemia was not found to reduce 1-year all-cause mortality. (Funded by the Swedish Heart-Lung Foundation and others; DETO2X-AMI ClinicalTrials.gov number, NCT01787110 .).