CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Mechanical complications of everolimus-eluting stents associated with adverse events: an intravascular ultrasound study Use of Intravascular Ultrasound Imaging in Percutaneous Coronary Intervention to Treat Left Main Coronary Artery Disease Plaque composition by intravascular ultrasound and distal embolization after percutaneous coronary intervention Circulating sST2 and catestatin levels in patients with acute worsening of heart failure: a report from the CATSTAT-HF study Clinical impact of intravascular ultrasound-guided chronic total occlusion intervention with zotarolimus-eluting versus biolimus-eluting stent implantation: randomized study Association of Smoking Status With Long‐Term Mortality and Health Status After Transcatheter Aortic Valve Replacement: Insights From the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies Cardiac Resynchronization Therapy in Inotrope-Dependent Heart Failure Patients - A Systematic Review and Meta-Analysis Cardiac Resynchronization Therapy and Ventricular Tachyarrhythmia Burden Canagliflozin and Cardiovascular and Renal Events in Type 2 Diabetes

Review ArticleApril 2017, Volume 69, Issue 16, Pages 2011-2022

JOURNAL:J Am Coll Cardiol. Article Link

Bleeding-Related Deaths in Relation to the Duration of Dual-Antiplatelet Therapy After Coronary Stenting

T Palmerini, LB Reggiani, GW Stone et al Keywords: drug-eluting stent; dual antiplatelet therapy

ABSTRACT

Background - Although some randomized controlled trials (RCTs) and meta-analyses have suggested that prolonged dual-antiplatelet therapy (DAPT) may be associated with increased mortality, the mechanistic underpinnings of this association remain unclear.

Objectives - The aim of this study was to analyze the associations among bleeding, mortality, and DAPT duration after drug-eluting stent implantation in a meta-analysis of RCTs.

Methods - RCTs comparing different DAPT durations after drug-eluting stent placement were sought through the MEDLINE, Embase, and Cochrane databases and the proceedings of international meetings. Deaths were considered possibly bleeding related if occurring within 1 year of the episodes of bleeding. Primary analysis was by intention-to-treat. Secondary analysis was performed in a modified intention-to-treat population in which events occurring when all patients were on DAPT were excluded.

Results - Individual patient data were obtained for 6 RCTs, and aggregate data were available for 12 RCTs. Patients with bleeding had significantly higher rates of mortality compared with those without, and in a time-adjusted multivariate analysis, bleeding was an independent predictor of mortality occurring within 1 year of the bleeding episode (hazard ratio: 6.93; 95% confidence interval: 4.53 to 10.60; p < 0.0001). Shorter DAPT was associated with lower rates of all-cause death compared with longer DAPT (hazard ratio: 0.85; 95% confidence interval: 0.73 to 1.00; p = 0.05), which was driven by lower rates of bleeding-related deaths with shorter DAPT compared with prolonged DAPT (hazard ratio: 0.65; 95% confidence interval: 0.43 to 0.99; p = 0.04). Mortality unrelated to bleeding was comparable between the 2 groups. Similar results were apparent in the modified intention-to-treat population.

Conclusions - Bleeding was strongly associated with the occurrence of mortality within 1 year after the bleeding event. Shorter compared with longer DAPT was associated with lower risk for bleeding-related death, a finding that may underlie the lower all-cause mortality with shorter DAPT in the RCTs of different DAPT durations after DES.