CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) Results From the OPINION Imaging Study Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure The year in cardiovascular medicine 2020: heart failure and cardiomyopathies Feasibility of Coronary Access and Aortic Valve Reintervention in Low-Risk TAVR Patients Impact of plaque components on no-reflow phenomenon after stent deployment in patients with acute coronary syndrome: a virtual histology-intravascular ultrasound analysis Atrial Fibrillation and the Prognostic Performance of Biomarkers in Heart Failure Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol Unexpectedly Low Natriuretic Peptide Levels in Patients With Heart Failure A three-vessel virtual histology intravascular ultrasound analysis of frequency and distribution of thin-cap fibroatheromas in patients with acute coronary syndrome or stable angina pectoris Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries

Review ArticleApril 2017, Volume 69, Issue 16, Pages 2011-2022

JOURNAL:J Am Coll Cardiol. Article Link

Bleeding-Related Deaths in Relation to the Duration of Dual-Antiplatelet Therapy After Coronary Stenting

T Palmerini, LB Reggiani, GW Stone et al Keywords: drug-eluting stent; dual antiplatelet therapy

ABSTRACT

Background - Although some randomized controlled trials (RCTs) and meta-analyses have suggested that prolonged dual-antiplatelet therapy (DAPT) may be associated with increased mortality, the mechanistic underpinnings of this association remain unclear.

Objectives - The aim of this study was to analyze the associations among bleeding, mortality, and DAPT duration after drug-eluting stent implantation in a meta-analysis of RCTs.

Methods - RCTs comparing different DAPT durations after drug-eluting stent placement were sought through the MEDLINE, Embase, and Cochrane databases and the proceedings of international meetings. Deaths were considered possibly bleeding related if occurring within 1 year of the episodes of bleeding. Primary analysis was by intention-to-treat. Secondary analysis was performed in a modified intention-to-treat population in which events occurring when all patients were on DAPT were excluded.

Results - Individual patient data were obtained for 6 RCTs, and aggregate data were available for 12 RCTs. Patients with bleeding had significantly higher rates of mortality compared with those without, and in a time-adjusted multivariate analysis, bleeding was an independent predictor of mortality occurring within 1 year of the bleeding episode (hazard ratio: 6.93; 95% confidence interval: 4.53 to 10.60; p < 0.0001). Shorter DAPT was associated with lower rates of all-cause death compared with longer DAPT (hazard ratio: 0.85; 95% confidence interval: 0.73 to 1.00; p = 0.05), which was driven by lower rates of bleeding-related deaths with shorter DAPT compared with prolonged DAPT (hazard ratio: 0.65; 95% confidence interval: 0.43 to 0.99; p = 0.04). Mortality unrelated to bleeding was comparable between the 2 groups. Similar results were apparent in the modified intention-to-treat population.

Conclusions - Bleeding was strongly associated with the occurrence of mortality within 1 year after the bleeding event. Shorter compared with longer DAPT was associated with lower risk for bleeding-related death, a finding that may underlie the lower all-cause mortality with shorter DAPT in the RCTs of different DAPT durations after DES.