CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Treatment of Very Small De Novo Coronary Artery Disease With 2.0 mm Drug-Coated Balloons Showed 1-Year Clinical Outcome Comparable With 2.0 mm Drug-Eluting Stents Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study Physiology-Based Revascularization: A New Approach to Plan and Optimize Percutaneous Coronary Intervention: State-of-the-Art Review Contemporary techniques in percutaneous coronary intervention for bifurcation lesions Clinical and angiographic outcomes of coronary dissection after paclitaxel-coated balloon angioplasty for small vessel coronary artery disease Drug-Coated Balloons for Coronary Artery Disease: Third Report of the International DCB Consensus Group Influence of Local Myocardial Damage on Index of Microcirculatory Resistance and Fractional Flow Reserve in Target and Nontarget Vascular Territories in a Porcine Microvascular Injury Model Drug-Coated Balloons: A Safe and Effective Alternative to Drug-Eluting Stents in Small Vessel Coronary Artery Disease Adaptive development of concomitant secondary mitral and tricuspid regurgitation after transcatheter aortic valve replacement Prediction of progression of coronary artery disease and clinical outcomes using vascular profiling of endothelial shear stress and arterial plaque characteristics: the PREDICTION Study

Review Article2018 Feb 2;13(15):e1804-e1811.

JOURNAL:EuroIntervention. Article Link

Step-by-step manual for planning and performing bifurcation PCI: a resource-tailored approach

Milasinovic D, Wijns W, Ntsekhe M et al. Keywords: drug-eluting stent; bifurcation; bare metal stent

ABSTRACT


As bifurcation PCI can often be resource-demanding due to the use of multiple guidewires, balloons and stents, different technical options are sometimes being explored, in different local settings, to meet the need of optimally treating a patient with a bifurcation lesion, while being confronted with limited material resources. Therefore, it seems important to keep a proper balance between what is recognised as the contemporary state of the art, and what is known to be potentially harmful and to be discouraged. Ultimately, the resource-tailored approach to bifurcation PCI may be characterised by the notion of minimum technical requirements for each step of a successful procedure. Hence, this paper describes the logical sequence of steps when performing bifurcationPCI with provisional SB stenting, starting with basic anatomy assessment and ending with the optimisation of MB stenting and the evaluation of the potential need to stent the SB, suggesting, for each step, the minimum technical requirement for a successful intervention.