CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines Transcatheter aortic-valve replacement with a self-expanding prosthesis Diagnostic performance of noninvasive myocardial perfusion imaging using single-photon emission computed tomography, cardiac magnetic resonance, and positron emission tomography imaging for the detection of obstructive coronary artery disease: a meta-analysis ACCF/AHA 2007 clinical expert consensus document on coronary artery calcium scoring by computed tomography in global cardiovascular risk assessment and in evaluation of patients with chest pain: a report of the American College of Cardiology Foundation Clinical Expert Consensus Task Force (ACCF/AHA Writing Committee to Update the 2000 Expert Consensus Document on Electron Beam Computed Tomography) developed in collaboration with the Society of Atherosclerosis Imaging and Prevention and the Society of Cardiovascular Computed Tomography Lipid-Modifying Agents, From Statins to PCSK9 Inhibitors: JACC Focus Seminar Cardiac surgery following transcatheter aortic valve replacement Lateral Wall Dysfunction Signals Onset of Progressive Heart Failure in Left Bundle Branch Block Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy) Contemporary real-world outcomes of surgical aortic valve replacement in 141,905 low-risk, intermediate-risk, and high-risk patients

Clinical TrialVolume 10, Issue 8, August 2017, Pages 869-879

JOURNAL:JACC Cardiovasc Imaging. Article Link

In Vivo Calcium Detection by Comparing Optical Coherence Tomography, Intravascular Ultrasound, and Angiography

Wang X, Matsumura M, Mintz GS et al. Keywords: angiography; calcification; intravascular ultrasound; optical coherence tomography

ABSTRACT

OBJECTIVES - The aim of this study was to evaluate optical coherence tomography (OCT) and intravascular ultrasound (IVUS) versus coronary angiography in the assessment of target lesion calcification and its effect on stent expansion.


BACKGROUD - IVUS is more sensitive than angiography in the detection of coronary artery calcium, but the relationship among IVUS, OCT, and angiography has not been studied.


METHODS - Overall, 440 lesions (440 patients with stable angina) underwent OCT- and IVUS-guided stent implantation. Coronary calcification was evaluated using: 1) angiography; 2) IVUS (maximum calcium angle and the surface pattern); and 3) OCT (mean and maximum calcium angle, calcium length, and maximum calciumthickness).


RESULTS - Median patient age was 66 years, and 82.5% were men. Among 440 lesions, calcium was detected by angiography in 40.2%, IVUS in 82.7%, and OCT in 76.8%. The maximum calcium angle, maximum calciumthickness, and calcium length by OCT or IVUS increased in relation to the increasing severity of angiographically visible calcium. In 13.2% of lesions with IVUS-detected calcium, calcium was either not visible or was underestimated (>90° smaller maximum arc) by OCT mostly due to superficial OCT plaque attenuation. In 21.6% of lesions with IVUS calcium angle >180°, angiography did not detect any calcium; these lesions had thinner and shorter calcium deposits as assessed using OCT, and final minimum stent area was larger compared to those with angiographically visible calcium. In lesions with thinner calcium deposits by OCT, IVUS detected a smooth surface with reverberations whereas thick calcium deposits were associated with an irregular surface without reverberations.


CONCLUSIONS - Angiographic detection of target lesion coronary calcium (compared to intravascular imaging) has not changed in the past 2 decades, and angiographically invisible calcium (only detectable by IVUS or OCT) did not appear to inhibit stent expansion.