CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Expansion or contraction of stenting in coronary artery disease? Randomized Evaluation of TriGuard 3 Cerebral Embolic Protection After Transcatheter Aortic Valve Replacement: REFLECT II Comparison of Outcomes of Percutaneous Coronary Intervention on Native Coronary Arteries Versus on Saphenous Venous Aorta Coronary Conduits in Patients With Low Left Ventricular Ejection Fraction and Impella Device Implantation Achieved or Attempted (from the PROTECT II Randomized Trial and the cVAD Registry) Impact of Staging Percutaneous Coronary Intervention in Left Main Artery Disease: Insights From the EXCEL Trial MINOCA: a heterogenous group of conditions associated with myocardial damage 2020 ACC Expert Consensus Decision Pathway on Management of Conduction Disturbances in Patients Undergoing Transcatheter Aortic Valve Replacement A Report of the American College of Cardiology Solution Set Oversight Committee Percutaneous Coronary Intervention Using Drug-Eluting Stents Versus Coronary Artery Bypass Grafting for Unprotected Left Main Coronary Artery Stenosis: A Meta-Analysis of Randomized Trials Evolution of antithrombotic therapy in patients undergoing percutaneous coronary intervention: a 40-year journey Transcatheter Aortic Valve Replacement: Role of Multimodality Imaging in Common and Complex Clinical Scenarios 5-Year Outcomes Comparing Surgical Versus Transcatheter Aortic Valve Replacement in Patients With Chronic Kidney Disease

Clinical Trial2018 Mar 20. pii: EIJ-D-17-00941.

JOURNAL:EuroIntervention. Article Link

Benefit of a new provisional stenting strategy: the re-Proximal Optimizing Technique. The rePOT clinical study

Dérimay F, Finet G, Souteyrand G et al. Keywords: left main bifurcation optical coherence tomography

ABSTRACT


AIMS - A new coronary bifurcation provisional stenting technique without kissing balloon, rePOT, associating proximal optimizing technique (POT), side-branch inflation and final POT, showed excellent mechanical results in a bench test. The present study sought to use optical coherence tomography (OCT) to quantify the mechanical results of rePOT in vivo in a large patient sample with complex coronary bifurcations.


METHODS AND RESULTS - 106 patients with coronary bifurcations were included in a multicenter prospective registry (left main, 40.6%; true Medina bifurcation, 39.6%). Three OCT runs were performed, at baseline, just after stent implantation and after the complete rePOT sequence, quantifying global malapposition, side-branch obstruction (SBO), and various geometric arterial criteria. RePOT was completed systematically. RePOT significantly reduced global strut malapposition from 18.9±13.4% just after stent implantation to 3.2±3.9% (p<0.05), residual SBO from 44.3±12.9% to 17.0±14.3% (p<0.05), and ellipticity index from 1.19±0.11 to 1.13±0.12 (p<0.05). Exhaustive 6-month follow-up found only 1 mother-vessel target lesion revascularization.

CONCLUSIONS - This clinical study of a large sample of complex coronary bifurcations with OCT analysis showed the benefit of the rePOT sequence in provisional stenting, replicating in vivo the excellent in vitro geometric results previously reported, and confirming ease of implementation and medium-term safety.