CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty Optical Coherence Tomography-Guided Percutaneous Coronary Intervention in ST-Segment-Elevation Myocardial Infarction: A Prospective Propensity-Matched Cohort of the Thrombectomy Versus Percutaneous Coronary Intervention Alone Trial A Randomized Trial Evaluating Online 3-Dimensional Optical Frequency Domain Imaging-Guided Percutaneous Coronary Intervention in Bifurcation Lesions Left main coronary artery compression in pulmonary hypertension Retrospective Comparison of Long-Term Clinical Outcomes Between Percutaneous Coronary Intervention and Medical Therapy in Stable Coronary Artery Disease With Gray Zone Fractional Flow Reserve - COMFORTABLE Retrospective Study Rotational Atherectomy in acute STEMI with heavily calcified culprit lesion is a rule breaking solution Robustness of Fractional Flow Reserve for Lesion Assessment in Non-Infarct-Related Arteries of Patients With Myocardial Infarction Optimal threshold of postintervention minimum stent area to predict in-stent restenosis in small coronary arteries: An optical coherence tomography analysis Pulmonary Artery Denervation: An Alternative Therapy for Pulmonary Hypertension Levosimendan Improves Hemodynamics and Exercise Tolerance in PH-HFpEF: Results of the Randomized Placebo-Controlled HELP Trial

Clinical Trial2018 Mar 20. pii: EIJ-D-17-00941.

JOURNAL:EuroIntervention. Article Link

Benefit of a new provisional stenting strategy: the re-Proximal Optimizing Technique. The rePOT clinical study

Dérimay F, Finet G, Souteyrand G et al. Keywords: left main bifurcation optical coherence tomography

ABSTRACT


AIMS - A new coronary bifurcation provisional stenting technique without kissing balloon, rePOT, associating proximal optimizing technique (POT), side-branch inflation and final POT, showed excellent mechanical results in a bench test. The present study sought to use optical coherence tomography (OCT) to quantify the mechanical results of rePOT in vivo in a large patient sample with complex coronary bifurcations.


METHODS AND RESULTS - 106 patients with coronary bifurcations were included in a multicenter prospective registry (left main, 40.6%; true Medina bifurcation, 39.6%). Three OCT runs were performed, at baseline, just after stent implantation and after the complete rePOT sequence, quantifying global malapposition, side-branch obstruction (SBO), and various geometric arterial criteria. RePOT was completed systematically. RePOT significantly reduced global strut malapposition from 18.9±13.4% just after stent implantation to 3.2±3.9% (p<0.05), residual SBO from 44.3±12.9% to 17.0±14.3% (p<0.05), and ellipticity index from 1.19±0.11 to 1.13±0.12 (p<0.05). Exhaustive 6-month follow-up found only 1 mother-vessel target lesion revascularization.

CONCLUSIONS - This clinical study of a large sample of complex coronary bifurcations with OCT analysis showed the benefit of the rePOT sequence in provisional stenting, replicating in vivo the excellent in vitro geometric results previously reported, and confirming ease of implementation and medium-term safety.