Drug-Coated Balloon-Only Percutaneous Coronary Intervention for the Treatment of De Novo Coronary Artery Disease: A Systematic Review Prediction of progression of coronary artery disease and clinical outcomes using vascular profiling of endothelial shear stress and arterial plaque characteristics: the PREDICTION Study Orbital atherectomy for treating de novo, severely calcified coronary lesions: 3-year results of the pivotal ORBIT II trial Drug-Coated Balloon Versus Drug-Eluting Stent for Small Coronary Vessel Disease: PICCOLETO II Randomized Clinical Trial Percutaneous Repair or Medical Treatment for Secondary Mitral Regurgitation: Outcomes at 2 years Treatment of Drug-Eluting Stent In-Stent Restenosis With Drug-Eluting Balloons: A Systematic Review and Meta-Analysis Percutaneous Pulmonary Angioplasty for Patients With Takayasu Arteritis and Pulmonary Hypertension Optical Coherence Tomography to Assess Proximal Side Optimization Technique in Crush Stenting Evolution of the Crush Technique for Bifurcation Stenting Fractional Flow Reserve–Guided PCI as Compared with Coronary Bypass Surgery

Clinical Trial2018 Mar 20. pii: EIJ-D-17-00941.

JOURNAL:EuroIntervention. Article Link

Benefit of a new provisional stenting strategy: the re-Proximal Optimizing Technique. The rePOT clinical study

Dérimay F, Finet G, Souteyrand G et al. Keywords: left main bifurcation optical coherence tomography

ABSTRACT


AIMS - A new coronary bifurcation provisional stenting technique without kissing balloon, rePOT, associating proximal optimizing technique (POT), side-branch inflation and final POT, showed excellent mechanical results in a bench test. The present study sought to use optical coherence tomography (OCT) to quantify the mechanical results of rePOT in vivo in a large patient sample with complex coronary bifurcations.


METHODS AND RESULTS - 106 patients with coronary bifurcations were included in a multicenter prospective registry (left main, 40.6%; true Medina bifurcation, 39.6%). Three OCT runs were performed, at baseline, just after stent implantation and after the complete rePOT sequence, quantifying global malapposition, side-branch obstruction (SBO), and various geometric arterial criteria. RePOT was completed systematically. RePOT significantly reduced global strut malapposition from 18.9±13.4% just after stent implantation to 3.2±3.9% (p<0.05), residual SBO from 44.3±12.9% to 17.0±14.3% (p<0.05), and ellipticity index from 1.19±0.11 to 1.13±0.12 (p<0.05). Exhaustive 6-month follow-up found only 1 mother-vessel target lesion revascularization.

CONCLUSIONS - This clinical study of a large sample of complex coronary bifurcations with OCT analysis showed the benefit of the rePOT sequence in provisional stenting, replicating in vivo the excellent in vitro geometric results previously reported, and confirming ease of implementation and medium-term safety.