CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Modifiable lifestyle factors and heart failure: A Mendelian randomization study Twelve or 30 months of dual antiplatelet therapy after drug-eluting stents Baseline Features of the VICTORIA (Vericiguat Global Study in Subjects With Heart Failure With Reduced Ejection Fraction) Trial Burden of Cardiovascular Diseases in China, 1990-2016: Findings From the 2016 Global Burden of Disease Study Temporal Trends in Transcatheter Aortic Valve Replacement in France: FRANCE 2 to FRANCE TAVI Heart Failure and Atrial Fibrillation, Like Fire and Fury Natriuretic Peptide-Guided Heart Failure Therapy After the GUIDE-IT Study Combined Tricuspid and Mitral Versus Isolated Mitral Valve Repair for Severe MR and TR: An Analysis From the TriValve and TRAMI Registries Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis Rationale and design of a randomized clinical trial comparing safety and efficacy of Myval transcatheter heart valve versus contemporary transcatheter heart valves in patients with severe symptomatic aortic valve stenosis: the LANDMARK trial

Clinical Trial2018 Mar 20. pii: EIJ-D-17-00941.

JOURNAL:EuroIntervention. Article Link

Benefit of a new provisional stenting strategy: the re-Proximal Optimizing Technique. The rePOT clinical study

Dérimay F, Finet G, Souteyrand G et al. Keywords: left main bifurcation optical coherence tomography

ABSTRACT


AIMS - A new coronary bifurcation provisional stenting technique without kissing balloon, rePOT, associating proximal optimizing technique (POT), side-branch inflation and final POT, showed excellent mechanical results in a bench test. The present study sought to use optical coherence tomography (OCT) to quantify the mechanical results of rePOT in vivo in a large patient sample with complex coronary bifurcations.


METHODS AND RESULTS - 106 patients with coronary bifurcations were included in a multicenter prospective registry (left main, 40.6%; true Medina bifurcation, 39.6%). Three OCT runs were performed, at baseline, just after stent implantation and after the complete rePOT sequence, quantifying global malapposition, side-branch obstruction (SBO), and various geometric arterial criteria. RePOT was completed systematically. RePOT significantly reduced global strut malapposition from 18.9±13.4% just after stent implantation to 3.2±3.9% (p<0.05), residual SBO from 44.3±12.9% to 17.0±14.3% (p<0.05), and ellipticity index from 1.19±0.11 to 1.13±0.12 (p<0.05). Exhaustive 6-month follow-up found only 1 mother-vessel target lesion revascularization.

CONCLUSIONS - This clinical study of a large sample of complex coronary bifurcations with OCT analysis showed the benefit of the rePOT sequence in provisional stenting, replicating in vivo the excellent in vitro geometric results previously reported, and confirming ease of implementation and medium-term safety.