Macrophage MST1/2 Disruption Impairs Post-Infarction Cardiac Repair via LTB4 A Novel Algorithm for Treating Chronic Total Coronary Artery Occlusion A Randomized Trial to Assess Regional Left Ventricular Function After Stent Implantation in Chronic Total Occlusion The REVASC Trial Long-Term Effect of Ultrathin-Strut Versus Thin-Strut Drug-Eluting Stents in Patients With Small Vessel Coronary Artery Disease Undergoing Percutaneous Coronary Intervention: A Subgroup Analysis of the BIOSCIENCE Randomized Trial Burden of 30-Day Readmissions After Percutaneous Coronary Intervention in 833,344 Patients in the United States: Predictors, Causes, and Cost Biolimus-A9 polymer-free coated stent in high bleeding risk patients with acute coronary syndrome: a Leaders Free ACS sub-study Frequency, Regional Variation, and Predictors of Undetermined Cause of Death in Cardiometabolic Clinical Trials: A Pooled Analysis of 9259 Deaths in 9 Trials Percutaneous coronary intervention using a combination of robotics and telecommunications by an operator in a separate physical location from the patient: an early exploration into the feasibility of telestenting (the REMOTE-PCI study) Transverse partial stent ablation with rotational atherectomy for suboptimal culotte technique in left main stem bifurcation Percutaneous Support Devices for Percutaneous Coronary Intervention

Review Article2015 Aug 15;386(9994):655-64.

JOURNAL:Lancet. Article Link

Percutaneous coronary interventional strategies for treatment of in-stent restenosis: a network meta-analysis

Siontis GC, Stefanini GG, Windecker S et al. Keywords: Plain Old Balloon Angioplasty; Vascular Brachytherapy; Cutting and Scoring Balloons; Rotational Atherectomy; Laser Techniques; Repeat Stenting with Bare Metal Stents; Repeat Stenting with Drug-Eluting Stents; Drug-Coated Balloons

ABSTRACT


BACKGROUND - Percutaneous coronary intervention (PCI) with drug-eluting stents is the standard of care for treatment of native coronary artery stenoses, but optimum treatment strategies for bare metal stent and drug-eluting stent in-stent restenosis (ISR) have not been established. We aimed to compare and rank percutaneous treatment strategies for ISR.


METHODS - We did a network meta-analysis to synthesise both direct and indirect evidence from relevant trials. We searched PubMed, the Cochrane Library Central Register of Controlled Trials, and Embase for randomised controlled trials published up to Oct 31, 2014, of different PCI strategies for treatment of any type of coronary ISR. The primary outcome was percent diameter stenosis at angiographic follow-up. This study is registered with PROSPERO, number CRD42014014191.

FINDINGS - We deemed 27 trials eligible, including 5923 patients, with follow-up ranging from 6 months to 60 months after the index intervention. Angiographic follow-up was available for 4975 (84%) of 5923 patients 6-12 months after the intervention. PCI with everolimus-eluting stents was the most effective treatment for percent diameter stenosis, with a difference of -9·0% (95% CI -15·8 to -2·2) versus drug-coated balloons (DCB), -9·4% (-17·4 to -1·4) versus sirolimus-eluting stents, -10·2% (-18·4 to -2·0) versus paclitaxel-eluting stents, -19·2% (-28·2 to -10·4) versus vascular brachytherapy, -23·4% (-36·2 to -10·8) versus bare metal stents, -24·2% (-32·2 to -16·4) versus balloon angioplasty, and -31·8% (-44·8 to -18·6) versus rotablation. DCB were ranked as the second most effective treatment, but without significant differences from sirolimus-eluting (-0·2% [95% CI -6·2 to 5·6]) or paclitaxel-eluting (-1·2% [-6·4 to 4·2]) stents.

INTERPRETATION - These findings suggest that two strategies should be considered for treatment of any type of coronary ISR: PCI with everolimus-eluting stents because of the best angiographic and clinical outcomes, and DCB because of its ability to provide favourable results without adding a new stent layer.

FUNDING - None.

Copyright © 2015 Elsevier Ltd. All rights reserved.