CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Reduced Leaflet Motion after Transcatheter Aortic-Valve Replacement Randomized Evaluation of Heart Failure With Preserved Ejection Fraction Patients With Acute Heart Failure and Dopamine - The ROPA-DOP Trial Study of Two Dose Regimens of Ticagrelor Compared with Clopidogrel in Patients Undergoing Percutaneous Coronary Intervention for Stable Coronary Artery Disease (STEEL-PCI) Primary Prevention Trial Designs Using Coronary Imaging: A National Heart, Lung, and Blood Institute Workshop Transcatheter Aortic Valve Replacement vs Surgical Replacement in Patients With Pure Aortic Insufficiency Why and How to Measure Aortic Valve Calcification in Patients With Aortic Stenosis The Utility of Rapid Atrial Pacing Immediately Post-TAVR to Predict the Need for Pacemaker Implantation Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies Comparison of plaque characteristics in narrowings with ST-elevation myocardial infarction (STEMI), non-STEMI/unstable angina pectoris and stable coronary artery disease (from the ADAPT-DES IVUS Substudy) Combined use of OCT and IVUS in spontaneous coronary artery dissection

Clinical TrialOctober 2017, Volume 120, Issue 7, Pages 1084–1089

JOURNAL:Am J Cardiol. Article Link

Intraluminal Intensity of Blood Speckle on Intravascular Ultrasound, a Novel Predictor of Periprocedural Myocardial Injury After Coronary Stenting

Okuya Y, Saito Y, Kitahara H et al. Keywords: acute coronary syndrome; intravascular ultrasound; percutaneous coronary intervention; periprocedural myocardial injury.

ABSTRACT

The difference in the intraluminal intensity of blood speckle (IBS) on integrated backscatter-intravascular ultrasound (IB-IVUS) across a coronary artery stenosis (i.e., ΔIBS) has previously shown a negative correlation with fractional flow reserve, reflecting an impaired coronary blood flow. Periprocedural myocardial injury (PMI) after coronary stenting has also been associated with coronary circulatory dysfunction. The aim of this study was to investigate the relation between ΔIBS after coronary stenting and PMI. A total of 180 patients who underwent elective coronary stenting under IVUS guidance for a single lesion were included. Intraluminal IBS was measured using IB-IVUS in cross sections at the ostium of the target vessel and at the distal reference of the stent. ΔIBS was calculated as (distal IBS value) - (ostium IBS value). PMI was defined as an elevation of troponin I >5 times the 99th percentile upper reference limit (>0.45 ng/ml) within 24 hours after the procedure. The mean ΔIBS after coronary stenting was 6.52 ± 5.71. There was a significantly greater use of the rotational atherectomy, the number of stents, the total stent length, and ΔIBS in patients with PMI than those without. In the receiver operating characteristic curve analysis, ΔIBS significantly predicted PMI (area under the curve 0.64, best cut-off value 7.88, p = 0.001). Multiple logistic regression analysis determined that the total stent length, the use of rotational atherectomy, and ΔIBS were independent predictors of PMI. In conclusion, greater ΔIBS assessed by IB-IVUS was significantly associated with PMI after coronary stenting in patients with a stable coronary artery disease.