CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Assessment and Quantitation of Stent Results by Intracoronary Optical Coherence Tomography Active SB-P Versus Conventional Approach to the Protection of High-Risk Side Branches: The CIT-RESOLVE Trial Edoxaban-based versus vitamin K antagonist-based antithrombotic regimen after successful coronary stenting in patients with atrial fibrillation (ENTRUST-AF PCI): a randomised, open-label, phase 3b trial Comprehensive Investigation of Circulating Biomarkers and their Causal Role in Atherosclerosis-related Risk Factors and Clinical Events Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study 2020 Expert Consensus Decision Pathway on Novel Therapies for Cardiovascular Risk Reduction in Patients With Type 2 Diabetes Global Approach to High Bleeding Risk Patients With Polymer-Free Drug-Coated Coronary Stents: The LF II Study Impact of intravascular ultrasound guidance in routine percutaneous coronary intervention for conventional lesions: data from the EXCELLENT trial EXCELling in Left Main Intervention Efficacy and safety of low-dose colchicine in patients with coronary disease: a systematic review and meta-analysis of randomized trials

Clinical TrialOctober 1, 2017; Volume 120, Issue 7, Pages 1084–1089

JOURNAL:Am J Cardiol. Article Link

Intraluminal Intensity of Blood Speckle on Intravascular Ultrasound, a Novel Predictor of Periprocedural Myocardial Injury After Coronary Stenting

Okuya Y, Saito Y, Kitahara H et al. Keywords: acute coronary syndrome; intravascular ultrasound; percutaneous coronary intervention; periprocedural myocardial injury.

ABSTRACT

The difference in the intraluminal intensity of blood speckle (IBS) on integrated backscatter-intravascular ultrasound (IB-IVUS) across a coronary artery stenosis (i.e., ΔIBS) has previously shown a negative correlation with fractional flow reserve, reflecting an impaired coronary blood flow. Periprocedural myocardial injury (PMI) after coronary stenting has also been associated with coronary circulatory dysfunction. The aim of this study was to investigate the relation between ΔIBS after coronary stenting and PMI. A total of 180 patients who underwent elective coronary stenting under IVUS guidance for a single lesion were included. Intraluminal IBS was measured using IB-IVUS in cross sections at the ostium of the target vessel and at the distal reference of the stent. ΔIBS was calculated as (distal IBS value) - (ostium IBS value). PMI was defined as an elevation of troponin I >5 times the 99th percentile upper reference limit (>0.45 ng/ml) within 24 hours after the procedure. The mean ΔIBS after coronary stenting was 6.52 ± 5.71. There was a significantly greater use of the rotational atherectomy, the number of stents, the total stent length, and ΔIBS in patients with PMI than those without. In the receiver operating characteristic curve analysis, ΔIBS significantly predicted PMI (area under the curve 0.64, best cut-off value 7.88, p = 0.001). Multiple logistic regression analysis determined that the total stent length, the use of rotational atherectomy, and ΔIBS were independent predictors of PMI. In conclusion, greater ΔIBS assessed by IB-IVUS was significantly associated with PMI after coronary stenting in patients with a stable coronary artery disease.