CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

The Art of SAPIEN 3 Transcatheter Mitral Valve Replacement in Valve-in-Ring and Valve-in-Mitral-Annular-Calcification Procedures Percutaneous Left Atrial Appendage Occlusion for Patients in Atrial Fibrillation Suboptimal for Warfarin Therapy: 5-year Results of the PLAATO (Percutaneous Left Atrial Appendage Transcatheter Occlusion) Study The management of secondary mitral regurgitation in patients with heart failure: a joint position statement from the Heart Failure Association (HFA), European Association of Cardiovascular Imaging (EACVI), European Heart Rhythm Association (EHRA), and European Association of Percutaneous Cardiovascular Interventions (EAPCI) of the ESC Prospective Evaluation of Transseptal TMVR for Failed Surgical Bioprostheses: MITRAL Trial Valve-in-Valve Arm 1-Year Outcomes Does pulsed field ablation regress over time? A quantitative temporal analysis of pulmonary vein isolation Current Status and Future Prospects of Transcatheter Mitral Valve Replacement: JACC State-of-the-Art Review Endoplasmic reticulum stress in doxorubicin-induced cardiotoxicity may be therapeutically targeted by natural and chemical compounds: A review Single direct oral anticoagulant therapy in stable patients with atrial fibrillation beyond 1 year after coronary stent implantation Strain-Guided Management of Potentially Cardiotoxic Cancer Therapy Functional Mitral Regurgitation Outcome and Grading in Heart Failure With Reduced Ejection Fraction

Clinical TrialOctober 1, 2017; Volume 120, Issue 7, Pages 1084–1089

JOURNAL:Am J Cardiol. Article Link

Intraluminal Intensity of Blood Speckle on Intravascular Ultrasound, a Novel Predictor of Periprocedural Myocardial Injury After Coronary Stenting

Okuya Y, Saito Y, Kitahara H et al. Keywords: acute coronary syndrome; intravascular ultrasound; percutaneous coronary intervention; periprocedural myocardial injury.

ABSTRACT

The difference in the intraluminal intensity of blood speckle (IBS) on integrated backscatter-intravascular ultrasound (IB-IVUS) across a coronary artery stenosis (i.e., ΔIBS) has previously shown a negative correlation with fractional flow reserve, reflecting an impaired coronary blood flow. Periprocedural myocardial injury (PMI) after coronary stenting has also been associated with coronary circulatory dysfunction. The aim of this study was to investigate the relation between ΔIBS after coronary stenting and PMI. A total of 180 patients who underwent elective coronary stenting under IVUS guidance for a single lesion were included. Intraluminal IBS was measured using IB-IVUS in cross sections at the ostium of the target vessel and at the distal reference of the stent. ΔIBS was calculated as (distal IBS value) - (ostium IBS value). PMI was defined as an elevation of troponin I >5 times the 99th percentile upper reference limit (>0.45 ng/ml) within 24 hours after the procedure. The mean ΔIBS after coronary stenting was 6.52 ± 5.71. There was a significantly greater use of the rotational atherectomy, the number of stents, the total stent length, and ΔIBS in patients with PMI than those without. In the receiver operating characteristic curve analysis, ΔIBS significantly predicted PMI (area under the curve 0.64, best cut-off value 7.88, p = 0.001). Multiple logistic regression analysis determined that the total stent length, the use of rotational atherectomy, and ΔIBS were independent predictors of PMI. In conclusion, greater ΔIBS assessed by IB-IVUS was significantly associated with PMI after coronary stenting in patients with a stable coronary artery disease.