CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Mortality after coronary artery bypass grafting versus percutaneous coronary intervention with stenting for coronary artery disease: a pooled analysis of individual patient data Lysed Erythrocyte Membranes Promote Vascular Calcification: Possible Role of Erythrocyte-Derived Nitric Oxide A randomized trial of bifurcation stenting technique in chronic total occlusions percutaneous coronary intervention Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromiummetallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial Low shear stress induces endothelial reactive oxygen species via the AT1R/eNOS/NO pathway Left main coronary artery compression in pulmonary hypertension Diagnostic accuracy of fractional flow reserve from anatomic CT angiography Optical coherence tomography and C-reactive protein in risk stratification of acute coronary syndromes Volumetric characterization of human coronary calcification by frequency-domain optical coherence tomography Meta-Analysis of Death and Myocardial Infarction in the DEFINE-FLAIR and iFR-SWEDEHEART Trials

Clinical Trial2014 Jan 28;129(4):463-70.

JOURNAL:Circulation. Article Link

Relationship between intravascular ultrasound guidance and clinical outcomes after drug-eluting stents: the assessment of dual antiplatelet therapy with drug-eluting stents (ADAPT-DES) study

Witzenbichler B, Maehara A, Weisz G et al. Keywords: IVUS; imaging; stent; thrombosis

ABSTRACT


BACKGROUND - Prior small to modest-sized studies suggest a benefit of intravascular ultrasound (IVUS) guidance in noncomplex lesions. Whether IVUS guidance is associated with improved clinical outcomes after drug-eluting stent (DES) implantation in an unrestricted patient population is unknown.


METHODS AND RESULTS - Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) was a prospective, multicenter, nonrandomized "all-comers" study of 8583 consecutive patients at 11 international centers designed to determine the frequency, timing, and correlates of stent thrombosis and adverse clinical events after DES. Propensity-adjusted multivariable analysis was performed to examine the relationship between IVUS guidance and 1-year outcomes. IVUS was utilized in 3349 patients (39%), and larger-diameter devices, longer stents, and/or higher inflation pressures were used in 74% of IVUS-guided cases. IVUS guidance compared with angiography guidance was associated with reduced 1-year rates of definite/probable stent thrombosis (0.6% [18 events] versus 1.0% [53 events]; adjusted hazard radio, 0.40; 95% confidence interval, 0.21-0.73; P=0.003), myocardial infarction (2.5% versus 3.7%; adjusted hazard radio, 0.66; 95% confidence interval, 0.49-0.88; P=0.004), and composite adjudicated major adverse cardiac events (ie, cardiac death, myocardial infarction, or stent thrombosis) (3.1% versus 4.7%; adjusted hazard radio, 0.70; 95% confidence interval, 0.55-0.88; P=0.002). The benefits of IVUS were especially evident in patients with acute coronary syndromes and complex lesions, although significant reductions in major adverse cardiac events were present in all patient subgroups those with including stable angina and single-vessel disease.

CONCLUSIONS - In ADAPT-DES, the largest study of IVUS use to date, IVUS guidance was associated with a reduction in stent thrombosis, myocardial infarction, and major adverse cardiac events within 1 year after DES implantation.

CLINICAL TRIAL REGISTRATION URL - http://www.clinicaltrials.gov. Unique identifier: NCT00638794.