CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Medical Therapy for CTEPH: Is There Still Space for More? Changes in Coronary Plaque Composition in Patients With Acute Myocardial Infarction Treated With High-Intensity Statin Therapy (IBIS-4): A Serial Optical Coherence Tomography Study Intravascular Ultrasound Pulmonary Artery Denervation to Treat Pulmonary Arterial Hypertension (TROPHY1): Multicenter, Early Feasibility Study Update on chronic thromboembolic pulmonary hypertension Microvascular disease in chronic thromboembolic pulmonary hypertension: a role for pulmonary veins and systemic vasculature Active and Passive Vaccination for Pulmonary Arterial Hypertension: A Novel Therapeutic Paradigm Developing a Mobile Application for Global Cardiovascular Education Tips of the dual-lumen microcatheter-facilitated reverse wire technique in percutaneous coronary interventions for markedly angulated bifurcated lesions Asia Pacific Consensus Document on Coronary Bifurcation Interventions Optimal Strategy for Provisional Side Branch Intervention in Coronary Bifurcation Lesions: 3-Year Outcomes of the SMART-STRATEGY Randomized Trial

Clinical Trial2014 Jan 28;129(4):463-70.

JOURNAL:Circulation. Article Link

Relationship between intravascular ultrasound guidance and clinical outcomes after drug-eluting stents: the assessment of dual antiplatelet therapy with drug-eluting stents (ADAPT-DES) study

Witzenbichler B, Maehara A, Weisz G et al. Keywords: IVUS; imaging; stent; thrombosis

ABSTRACT


BACKGROUND - Prior small to modest-sized studies suggest a benefit of intravascular ultrasound (IVUS) guidance in noncomplex lesions. Whether IVUS guidance is associated with improved clinical outcomes after drug-eluting stent (DES) implantation in an unrestricted patient population is unknown.


METHODS AND RESULTS - Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) was a prospective, multicenter, nonrandomized "all-comers" study of 8583 consecutive patients at 11 international centers designed to determine the frequency, timing, and correlates of stent thrombosis and adverse clinical events after DES. Propensity-adjusted multivariable analysis was performed to examine the relationship between IVUS guidance and 1-year outcomes. IVUS was utilized in 3349 patients (39%), and larger-diameter devices, longer stents, and/or higher inflation pressures were used in 74% of IVUS-guided cases. IVUS guidance compared with angiography guidance was associated with reduced 1-year rates of definite/probable stent thrombosis (0.6% [18 events] versus 1.0% [53 events]; adjusted hazard radio, 0.40; 95% confidence interval, 0.21-0.73; P=0.003), myocardial infarction (2.5% versus 3.7%; adjusted hazard radio, 0.66; 95% confidence interval, 0.49-0.88; P=0.004), and composite adjudicated major adverse cardiac events (ie, cardiac death, myocardial infarction, or stent thrombosis) (3.1% versus 4.7%; adjusted hazard radio, 0.70; 95% confidence interval, 0.55-0.88; P=0.002). The benefits of IVUS were especially evident in patients with acute coronary syndromes and complex lesions, although significant reductions in major adverse cardiac events were present in all patient subgroups those with including stable angina and single-vessel disease.

CONCLUSIONS - In ADAPT-DES, the largest study of IVUS use to date, IVUS guidance was associated with a reduction in stent thrombosis, myocardial infarction, and major adverse cardiac events within 1 year after DES implantation.

CLINICAL TRIAL REGISTRATION URL - http://www.clinicaltrials.gov. Unique identifier: NCT00638794.