CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Treatment effects of systematic two-stent and provisional stenting techniques in patients with complex coronary bifurcation lesions: rationale and design of a prospective, randomised and multicentre DEFINITION II trial 1-Year Outcomes of Patients Undergoing Primary Angioplasty for Myocardial Infarction Treated With Prasugrel Versus Ticagrelor Risk of Myocardial Infarction in Anticoagulated Patients With Atrial Fibrillation 2015 ESC/ERS Guidelines for the diagnosis and treatment of pulmonary hypertension: The Joint Task Force for the Diagnosis and Treatment of Pulmonary Hypertension of the European Society of Cardiology (ESC) and the European Respiratory Society (ERS): Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC), International Society for Heart and Lung Transplantation (ISHLT) Effect of Lipoprotein (a) Levels on Long-term Cardiovascular Outcomes in Patients with Myocardial Infarction with Nonobstructive Coronary Arteries Optical coherence tomography imaging during percutaneous coronary intervention impacts physician decision-making: ILUMIEN I study Long-Term Coronary Functional Assessment of the Infarct-Related Artery Treated With Everolimus-Eluting Bioresorbable Scaffolds or Everolimus-Eluting Metallic Stents: Insights of the TROFI II Trial Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Metallic Stents Off-hour presentation and outcomes in patients with acute myocardial infarction: systematic review and meta-analysis How Low to Go With Glucose, Cholesterol, and Blood Pressure in Primary Prevention of CVD

Clinical Trial2014 Jan 28;129(4):463-70.

JOURNAL:Circulation. Article Link

Relationship between intravascular ultrasound guidance and clinical outcomes after drug-eluting stents: the assessment of dual antiplatelet therapy with drug-eluting stents (ADAPT-DES) study

Witzenbichler B, Maehara A, Weisz G et al. Keywords: IVUS; imaging; stent; thrombosis

ABSTRACT


BACKGROUND - Prior small to modest-sized studies suggest a benefit of intravascular ultrasound (IVUS) guidance in noncomplex lesions. Whether IVUS guidance is associated with improved clinical outcomes after drug-eluting stent (DES) implantation in an unrestricted patient population is unknown.


METHODS AND RESULTS - Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) was a prospective, multicenter, nonrandomized "all-comers" study of 8583 consecutive patients at 11 international centers designed to determine the frequency, timing, and correlates of stent thrombosis and adverse clinical events after DES. Propensity-adjusted multivariable analysis was performed to examine the relationship between IVUS guidance and 1-year outcomes. IVUS was utilized in 3349 patients (39%), and larger-diameter devices, longer stents, and/or higher inflation pressures were used in 74% of IVUS-guided cases. IVUS guidance compared with angiography guidance was associated with reduced 1-year rates of definite/probable stent thrombosis (0.6% [18 events] versus 1.0% [53 events]; adjusted hazard radio, 0.40; 95% confidence interval, 0.21-0.73; P=0.003), myocardial infarction (2.5% versus 3.7%; adjusted hazard radio, 0.66; 95% confidence interval, 0.49-0.88; P=0.004), and composite adjudicated major adverse cardiac events (ie, cardiac death, myocardial infarction, or stent thrombosis) (3.1% versus 4.7%; adjusted hazard radio, 0.70; 95% confidence interval, 0.55-0.88; P=0.002). The benefits of IVUS were especially evident in patients with acute coronary syndromes and complex lesions, although significant reductions in major adverse cardiac events were present in all patient subgroups those with including stable angina and single-vessel disease.

CONCLUSIONS - In ADAPT-DES, the largest study of IVUS use to date, IVUS guidance was associated with a reduction in stent thrombosis, myocardial infarction, and major adverse cardiac events within 1 year after DES implantation.

CLINICAL TRIAL REGISTRATION URL - http://www.clinicaltrials.gov. Unique identifier: NCT00638794.