2-year outcomes with the Absorb bioresorbable scaffold for treatment of coronary artery disease: a systematic review and meta-analysis of seven randomised trials with an individual patient data substudy Changes in high-sensitivity troponin after drug-coated balloon angioplasty for drug-eluting stent restenosis sST2 Predicts Outcome in Chronic Heart Failure Beyond NT−proBNP and High-Sensitivity Troponin T Treating Multivessel Coronary Artery Disease in ST-Segment Elevation Myocardial Infarction: Why, How, and When? Home-Based Cardiac Rehabilitation: A Scientific Statement From the American Association of Cardiovascular and Pulmonary Rehabilitation, the American Heart Association, and the American College of Cardiology Improving the Design of Future PCI Trials for Stable Coronary Artery Disease: JACC State-of-the-Art Review Cardiorespiratory Fitness and Mortality in Healthy Men and Women Classification of Deaths in Cardiovascular Outcomes Trials Known Unknowns and Unknown Unknowns SGLT2 Inhibitors in Patients With Heart Failure With Reduced Ejection Fraction: A Meta-Analysis of the EMPEROR-Reduced and DAPA-HF Trials The Current State of Left Main Percutaneous Coronary Intervention

Clinical Trial2014 Jan 28;129(4):463-70.

JOURNAL:Circulation. Article Link

Relationship between intravascular ultrasound guidance and clinical outcomes after drug-eluting stents: the assessment of dual antiplatelet therapy with drug-eluting stents (ADAPT-DES) study

Witzenbichler B, Maehara A, Weisz G et al. Keywords: IVUS; imaging; stent; thrombosis

ABSTRACT


BACKGROUND - Prior small to modest-sized studies suggest a benefit of intravascular ultrasound (IVUS) guidance in noncomplex lesions. Whether IVUS guidance is associated with improved clinical outcomes after drug-eluting stent (DES) implantation in an unrestricted patient population is unknown.


METHODS AND RESULTS - Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) was a prospective, multicenter, nonrandomized "all-comers" study of 8583 consecutive patients at 11 international centers designed to determine the frequency, timing, and correlates of stent thrombosis and adverse clinical events after DES. Propensity-adjusted multivariable analysis was performed to examine the relationship between IVUS guidance and 1-year outcomes. IVUS was utilized in 3349 patients (39%), and larger-diameter devices, longer stents, and/or higher inflation pressures were used in 74% of IVUS-guided cases. IVUS guidance compared with angiography guidance was associated with reduced 1-year rates of definite/probable stent thrombosis (0.6% [18 events] versus 1.0% [53 events]; adjusted hazard radio, 0.40; 95% confidence interval, 0.21-0.73; P=0.003), myocardial infarction (2.5% versus 3.7%; adjusted hazard radio, 0.66; 95% confidence interval, 0.49-0.88; P=0.004), and composite adjudicated major adverse cardiac events (ie, cardiac death, myocardial infarction, or stent thrombosis) (3.1% versus 4.7%; adjusted hazard radio, 0.70; 95% confidence interval, 0.55-0.88; P=0.002). The benefits of IVUS were especially evident in patients with acute coronary syndromes and complex lesions, although significant reductions in major adverse cardiac events were present in all patient subgroups those with including stable angina and single-vessel disease.

CONCLUSIONS - In ADAPT-DES, the largest study of IVUS use to date, IVUS guidance was associated with a reduction in stent thrombosis, myocardial infarction, and major adverse cardiac events within 1 year after DES implantation.

CLINICAL TRIAL REGISTRATION URL - http://www.clinicaltrials.gov. Unique identifier: NCT00638794.