CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Fractional Flow Reserve–Guided PCI for Stable Coronary Artery Disease Meta-Analysis of Death and Myocardial Infarction in the DEFINE-FLAIR and iFR-SWEDEHEART Trials Left main coronary artery compression in pulmonary hypertension Prognostic implications of ischemia with nonobstructive coronary arteries (INOCA): Understanding risks for improving treatment Updated clinical classification of pulmonary hypertension The EBC TWO Study (European Bifurcation Coronary TWO): A Randomized Comparison of Provisional T-Stenting Versus a Systematic 2 Stent Culotte Strategy in Large Caliber True Bifurcations OCT compared with IVUS in a coronary lesion assessment: the OPUS-CLASS study Retrospective Comparison of Long-Term Clinical Outcomes Between Percutaneous Coronary Intervention and Medical Therapy in Stable Coronary Artery Disease With Gray Zone Fractional Flow Reserve - COMFORTABLE Retrospective Study Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation

Clinical Trial2015 Nov 24;314(20):2155-63.

JOURNAL:JAMA. Article Link

Effect of Intravascular Ultrasound-Guided vs Angiography-Guided Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial

Hong SJ, Kim BK, IVUS-XPL Investigators. Keywords: IVUS; RCT; PCI; outcome

ABSTRACT


IMPORTANCE - Use of intravascular ultrasound (IVUS) promotes better clinical outcomes for coronary intervention in complex coronary lesions. However, randomized data demonstrating the clinical usefulness of IVUS are limited for lesions treated with drug-eluting stents.


OBJECTIVE - To determine whether the long-term clinical outcomes with IVUS-guided drug-eluting stent implantation are superior to those with angiography-guided implantation in patients with long coronary lesions.

DESIGN, SETTING, AND PARTICIPANTS - The Impact of Intravascular Ultrasound Guidance on Outcomes of Xience Prime Stents in Long Lesions (IVUS-XPL) randomized, multicenter trial was conducted in 1400 patients with long coronary lesions (implanted stent ≥28 mm in length) between October 2010 and July 2014 at 20 centers in Korea.

INTERVENTIONS - Patients were randomly assigned to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation.

MAIN OUTCOMES AND MEASURES - Primary outcome measure was the composite of major adverse cardiac events, including cardiac death, target lesion-related myocardial infarction, or ischemia-driven target lesion revascularization at 1 year, analyzed by intention-to-treat.

RESULTS - One-year follow-up was complete in 1323 patients (94.5%). Major adverse cardiac events at 1 year occurred in 19 patients (2.9%) undergoing IVUS-guided and in 39 patients (5.8%) undergoing angiography-guided stent implantation (absolute difference, -2.97% [95% CI, -5.14% to -0.79%]) (hazard ratio [HR], 0.48 [95% CI, 0.28 to 0.83], P = .007). The difference was driven by a lower risk of ischemia-driven target lesion revascularization in patients undergoing IVUS-guided (17 [2.5%]) compared with angiography-guided (33 [5.0%]) stent implantation (HR, 0.51 [95% CI, 0.28 to 0.91], P = .02). Cardiac death and target lesion-related myocardial infarction were not significantly different between the 2 groups. For cardiac death, there were 3 patients (0.4%) in the IVUS-guided group and 5 patients (0.7%) in the angiography-guided group (HR, 0.60 [95% CI, 0.14 to 2.52], P = .48). Target lesion-related myocardial infarction occurred in 1 patient (0.1%) in the angiography-guided stent implantation group (P = .32).

CONCLUSIONS AND RELEVANCE - Among patients requiring long coronary stent implantation, the use of IVUS-guided everolimus-eluting stent implantation, compared with angiography-guided stent implantation, resulted in a significantly lower rate of the composite of major adverse cardiac events at 1 year. These differences were primarily due to lower risk of target lesion revascularization.

TRIAL REGISTRATION - clinicaltrials.gov Identifier: NCT01308281.