Transcatheter Interventions for Tricuspid Valve Disease: What to Do and Who to Do it On Optical Coherence Tomography to Assess Proximal Side Optimization Technique in Crush Stenting Italian Society of Interventional Cardiology (GIse) Registry Of Transcatheter Treatment of Mitral Valve RegurgitaTiOn (GIOTTO): Impact of Valve Disease Etiology and Residual Mitral Regurgitation after MitraClip Implantation Pathophysiology, diagnosis and new therapeutic approaches for ischemic mitral regurgitation An artificial intelligence-enabled ECG algorithm for the identification of patients with atrial fibrillation during sinus rhythm: a retrospective analysis of outcome prediction Risk of Atrial Fibrillation According to Cancer Type: A Nationwide Population-Based Study Incidence and Standardized Definitions of Mitral Valve Leaflet Adverse Events After Transcatheter Mitral Valve Repair: the EXPAND Study Outcomes of TTVI in Patients With Pacemaker or Defibrillator Leads: Data From the TriValve Registry Novel Transcatheter Mitral Valve Prosthesis for Patients With Severe Mitral Annular Calcification High Coronary Shear Stress in Patients With Coronary Artery Disease Predicts Myocardial Infarction

Clinical Trial2015 Nov 24;314(20):2155-63.

JOURNAL:JAMA. Article Link

Effect of Intravascular Ultrasound-Guided vs Angiography-Guided Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial

Hong SJ, Kim BK, IVUS-XPL Investigators. Keywords: IVUS; RCT; PCI; outcome

ABSTRACT


IMPORTANCE - Use of intravascular ultrasound (IVUS) promotes better clinical outcomes for coronary intervention in complex coronary lesions. However, randomized data demonstrating the clinical usefulness of IVUS are limited for lesions treated with drug-eluting stents.


OBJECTIVE - To determine whether the long-term clinical outcomes with IVUS-guided drug-eluting stent implantation are superior to those with angiography-guided implantation in patients with long coronary lesions.

DESIGN, SETTING, AND PARTICIPANTS - The Impact of Intravascular Ultrasound Guidance on Outcomes of Xience Prime Stents in Long Lesions (IVUS-XPL) randomized, multicenter trial was conducted in 1400 patients with long coronary lesions (implanted stent ≥28 mm in length) between October 2010 and July 2014 at 20 centers in Korea.

INTERVENTIONS - Patients were randomly assigned to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation.

MAIN OUTCOMES AND MEASURES - Primary outcome measure was the composite of major adverse cardiac events, including cardiac death, target lesion-related myocardial infarction, or ischemia-driven target lesion revascularization at 1 year, analyzed by intention-to-treat.

RESULTS - One-year follow-up was complete in 1323 patients (94.5%). Major adverse cardiac events at 1 year occurred in 19 patients (2.9%) undergoing IVUS-guided and in 39 patients (5.8%) undergoing angiography-guided stent implantation (absolute difference, -2.97% [95% CI, -5.14% to -0.79%]) (hazard ratio [HR], 0.48 [95% CI, 0.28 to 0.83], P = .007). The difference was driven by a lower risk of ischemia-driven target lesion revascularization in patients undergoing IVUS-guided (17 [2.5%]) compared with angiography-guided (33 [5.0%]) stent implantation (HR, 0.51 [95% CI, 0.28 to 0.91], P = .02). Cardiac death and target lesion-related myocardial infarction were not significantly different between the 2 groups. For cardiac death, there were 3 patients (0.4%) in the IVUS-guided group and 5 patients (0.7%) in the angiography-guided group (HR, 0.60 [95% CI, 0.14 to 2.52], P = .48). Target lesion-related myocardial infarction occurred in 1 patient (0.1%) in the angiography-guided stent implantation group (P = .32).

CONCLUSIONS AND RELEVANCE - Among patients requiring long coronary stent implantation, the use of IVUS-guided everolimus-eluting stent implantation, compared with angiography-guided stent implantation, resulted in a significantly lower rate of the composite of major adverse cardiac events at 1 year. These differences were primarily due to lower risk of target lesion revascularization.

TRIAL REGISTRATION - clinicaltrials.gov Identifier: NCT01308281.