CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Association of loop diuretics use and dose with outcomes in outpatients with heart failure: a systematic review and meta-analysis of observational studies involving 96,959 patients Aggressive lipid-lowering therapy after percutaneous coronary intervention – for whom and how? 2016 ACC/AHA guideline focused update on duration of dual antiplatelet therapy in patients with coronary artery disease: A report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines Intravascular Ultrasound Guidance Reduces Cardiac Death and Coronary Revascularization in Patients Undergoing Drug-Eluting Stent Implantation: Results From a Meta-Analysis of 9 Randomized Trials and 4724 Patients Antithrombotics From Aspirin to DOACs in Coronary Artery Disease and Atrial Fibrillation (Part 3/5) A Genotype-Guided Strategy for Oral P2Y12 Inhibitors in Primary PCI Tissue characterisation of atherosclerotic plaque in the left main: an in vivo intravascular ultrasound radiofrequency data analysis Treatment strategies for coronary in-stent restenosis: systematic review and hierarchical Bayesian network meta-analysis of 24 randomised trials and 4880 patients The Hospital Readmissions Reduction Program Nationwide Perspectives and Recommendations: A JACC: Heart Failure Position Paper Impact of the complexity of bifurcation lesions treated with drug-eluting stents: the DEFINITION study (Definitions and impact of complEx biFurcation lesIons on clinical outcomes after percutaNeous coronary IntervenTIOn using drug-eluting steNts)

Clinical Trial2015 Nov 24;314(20):2155-63.

JOURNAL:JAMA. Article Link

Effect of Intravascular Ultrasound-Guided vs Angiography-Guided Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial

Hong SJ, Kim BK, IVUS-XPL Investigators. Keywords: IVUS; RCT; PCI; outcome

ABSTRACT


IMPORTANCE - Use of intravascular ultrasound (IVUS) promotes better clinical outcomes for coronary intervention in complex coronary lesions. However, randomized data demonstrating the clinical usefulness of IVUS are limited for lesions treated with drug-eluting stents.


OBJECTIVE - To determine whether the long-term clinical outcomes with IVUS-guided drug-eluting stent implantation are superior to those with angiography-guided implantation in patients with long coronary lesions.

DESIGN, SETTING, AND PARTICIPANTS - The Impact of Intravascular Ultrasound Guidance on Outcomes of Xience Prime Stents in Long Lesions (IVUS-XPL) randomized, multicenter trial was conducted in 1400 patients with long coronary lesions (implanted stent ≥28 mm in length) between October 2010 and July 2014 at 20 centers in Korea.

INTERVENTIONS - Patients were randomly assigned to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation.

MAIN OUTCOMES AND MEASURES - Primary outcome measure was the composite of major adverse cardiac events, including cardiac death, target lesion-related myocardial infarction, or ischemia-driven target lesion revascularization at 1 year, analyzed by intention-to-treat.

RESULTS - One-year follow-up was complete in 1323 patients (94.5%). Major adverse cardiac events at 1 year occurred in 19 patients (2.9%) undergoing IVUS-guided and in 39 patients (5.8%) undergoing angiography-guided stent implantation (absolute difference, -2.97% [95% CI, -5.14% to -0.79%]) (hazard ratio [HR], 0.48 [95% CI, 0.28 to 0.83], P = .007). The difference was driven by a lower risk of ischemia-driven target lesion revascularization in patients undergoing IVUS-guided (17 [2.5%]) compared with angiography-guided (33 [5.0%]) stent implantation (HR, 0.51 [95% CI, 0.28 to 0.91], P = .02). Cardiac death and target lesion-related myocardial infarction were not significantly different between the 2 groups. For cardiac death, there were 3 patients (0.4%) in the IVUS-guided group and 5 patients (0.7%) in the angiography-guided group (HR, 0.60 [95% CI, 0.14 to 2.52], P = .48). Target lesion-related myocardial infarction occurred in 1 patient (0.1%) in the angiography-guided stent implantation group (P = .32).

CONCLUSIONS AND RELEVANCE - Among patients requiring long coronary stent implantation, the use of IVUS-guided everolimus-eluting stent implantation, compared with angiography-guided stent implantation, resulted in a significantly lower rate of the composite of major adverse cardiac events at 1 year. These differences were primarily due to lower risk of target lesion revascularization.

TRIAL REGISTRATION - clinicaltrials.gov Identifier: NCT01308281.