CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study Contemporary techniques in percutaneous coronary intervention for bifurcation lesions Drug-Coated Balloons for Coronary Artery Disease: Third Report of the International DCB Consensus Group Treatment of Very Small De Novo Coronary Artery Disease With 2.0 mm Drug-Coated Balloons Showed 1-Year Clinical Outcome Comparable With 2.0 mm Drug-Eluting Stents Influence of Local Myocardial Damage on Index of Microcirculatory Resistance and Fractional Flow Reserve in Target and Nontarget Vascular Territories in a Porcine Microvascular Injury Model Adaptive development of concomitant secondary mitral and tricuspid regurgitation after transcatheter aortic valve replacement Clinical and angiographic outcomes of coronary dissection after paclitaxel-coated balloon angioplasty for small vessel coronary artery disease Long-term efficacy and safety of drug-coated balloons versus drug-eluting stents for small coronary artery disease (BASKET-SMALL 2): 3-year follow-up of a randomised, non-inferiority trial Optical Coherence Tomography–Defined Plaque Vulnerability in Relation to Functional Stenosis Severity and Microvascular Dysfunction Drug-Coated Balloon-Only Percutaneous Coronary Intervention for the Treatment of De Novo Coronary Artery Disease: A Systematic Review

Review Article 2009 Jan;2(1):65-72.

JOURNAL:JACC Cardiovasc Interv. Article Link

Attenuated plaque detected by intravascular ultrasound: clinical, angiographic, and morphologic features and post-percutaneous coronary intervention complications in patients with acute coronary syndromes

Lee SY, Mintz GS, Kim SY et al. Keywords: attenuated plaque; IVUS; ACS

ABSTRACT


OBJECTIVES - We evaluated the clinical significance of attenuated plaque (hypoechoic plaque with deep ultrasound attenuation).


BACKGROUND - Attenuated plaques are unusual intravascular ultrasound (IVUS) findings in patients with acute coronary syndrome (ACS).

METHODS - We reviewed clinical presentations and angiographic and pre-intervention IVUS findings in 293 ACS patients undergoing percutaneous coronary intervention (PCI) without a distal protection device: 187 with non-ST-segment elevation myocardial infarction (NSTEMI) and 106 with ST-segment elevation myocardial infarction (STEMI).

RESULTS - Attenuated plaque was observed in 75 patients (25.6%): 39.6% of STEMI versus 17.6% of NSTEMI (p < 0.001). (We also reviewed 100 randomly selected patients with stable angina and pre-intervention IVUS; none had attenuated plaque.) Overall, in ACS patients with attenuated plaques: 1) the level of C-reactive protein was higher; 2) angiographic thrombus and initial coronary flow Thrombolysis In Myocardial Infarction flow grade <2 were more common; and 3) IVUS lesion site plaque burden and remodeling index were significantly greater, lesion site luminal dimensions significantly smaller, and thrombus, positive remodeling, and plaque rupture were more common. No-reflow (26.7% vs. 4.6%, p < 0.001) and deteriorated post-PCI coronary blood flow (8.0% vs. 2.8%, p = 0.001) were higher. In ACS patients with normal coronary blood flow at baseline, deterioration in the coronary blood flow post-PCI was more common in lesions with attenuated plaque.

CONCLUSIONS - Attenuated plaque was more common in ACS patients with STEMI than NSTEMI. Attenuated plaque in ACS patients was associated with a higher C-reactive protein level, more severe and complex lesion morphology, reduced coronary blood flow before PCI, and especially no-reflow after PCI.