In-Hospital Costs and Costs of Complications of Chronic Total Occlusion Angioplasty Insights From the OPEN-CTO Registry 2020 AHA/ACC Key Data Elements and Definitions for Coronary Revascularization A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Data Standards (Writing Committee to Develop Clinical Data Standards for Coronary Revascularization) Improving the Design of Future PCI Trials for Stable Coronary Artery Disease: JACC State-of-the-Art Review Drug-eluting balloons in coronary interventions: the quiet revolution? Left Ventricular Assist Devices: Synergistic Model Between Technology and Medicine Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis Mortality Differences Associated With Treatment Responses in CANTOS and FOURIER: Insights and Implications Catheterization Laboratory Considerations During the Coronavirus (COVID-19) Pandemic: From the ACC’s Interventional Council and SCAI Ejection Fraction Pros and Cons: JACC State-of-the-Art Review Classification of Deaths in Cardiovascular Outcomes Trials Known Unknowns and Unknown Unknowns

Review Article 2009 Jan;2(1):65-72.

JOURNAL:JACC Cardiovasc Interv. Article Link

Attenuated plaque detected by intravascular ultrasound: clinical, angiographic, and morphologic features and post-percutaneous coronary intervention complications in patients with acute coronary syndromes

Lee SY, Mintz GS, Kim SY et al. Keywords: attenuated plaque; IVUS; ACS

ABSTRACT


OBJECTIVES - We evaluated the clinical significance of attenuated plaque (hypoechoic plaque with deep ultrasound attenuation).


BACKGROUND - Attenuated plaques are unusual intravascular ultrasound (IVUS) findings in patients with acute coronary syndrome (ACS).

METHODS - We reviewed clinical presentations and angiographic and pre-intervention IVUS findings in 293 ACS patients undergoing percutaneous coronary intervention (PCI) without a distal protection device: 187 with non-ST-segment elevation myocardial infarction (NSTEMI) and 106 with ST-segment elevation myocardial infarction (STEMI).

RESULTS - Attenuated plaque was observed in 75 patients (25.6%): 39.6% of STEMI versus 17.6% of NSTEMI (p < 0.001). (We also reviewed 100 randomly selected patients with stable angina and pre-intervention IVUS; none had attenuated plaque.) Overall, in ACS patients with attenuated plaques: 1) the level of C-reactive protein was higher; 2) angiographic thrombus and initial coronary flow Thrombolysis In Myocardial Infarction flow grade <2 were more common; and 3) IVUS lesion site plaque burden and remodeling index were significantly greater, lesion site luminal dimensions significantly smaller, and thrombus, positive remodeling, and plaque rupture were more common. No-reflow (26.7% vs. 4.6%, p < 0.001) and deteriorated post-PCI coronary blood flow (8.0% vs. 2.8%, p = 0.001) were higher. In ACS patients with normal coronary blood flow at baseline, deterioration in the coronary blood flow post-PCI was more common in lesions with attenuated plaque.