CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Intravascular ultrasound enhances the safety of rotational atherectomy Clinical Characteristics and Long-Term Outcomes of Rotational Atherectomy-J2T Multicenter Registry Percutaneous Treatment and Outcomes of Small Coronary Vessels: A SCAAR Report Pulmonary hypertension is associated with an increased incidence of NAFLD: A retrospective cohort study of 18,910 patients Procedural Success and Outcomes With Increasing Use of Enabling Strategies for Chronic Total Occlusion Intervention North American Expert Review of Rotational Atherectomy Orbital atherectomy for the treatment of small (2.5mm) severely calcified coronary lesions: ORBIT II sub-analysis The Regulation of Pulmonary Vascular Tone by Neuropeptides and the Implications for Pulmonary Hypertension Coronary Calcification and Long-Term Outcomes According to Drug-Eluting Stent Generation Pivotal trial to evaluate the safety and efficacy of the orbital atherectomy system in treating de novo, severely calcified coronary lesions (ORBIT II)

Original Research2011 May;4(5):495-502.

JOURNAL:JACC Cardiovasc Interv. Article Link

The relationship between attenuated plaque identified by intravascular ultrasound and no-reflow after stenting in acute myocardial infarction: the HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) trial

Wu X, Mintz GS, Xu K et al. Keywords: AMI; IVUS; no-reflow

ABSTRACT


OBJECTIVESThe aim of this study was to understand the impact of attenuated plaque on distal embolization during stent implantation in patients with acute myocardial infarction (AMI).


BACKGROUND - Attenuated plaques identified by grayscale intravascular ultrasound (IVUS) might predict transient deterioration in coronary flow and/or no-reflow during percutaneous coronary intervention (PCI).

METHODS - We analyzed clinical, angiographic, and IVUS data from 364 patients (n = 364 infarct-related arteries) enrolled in the randomized HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) trial. No-reflow was final Thrombolysis In Myocardial Infarction (TIMI) flow grade ≤2 in the absence of mechanical obstruction. Attenuated plaque was hypoechoic or mixed atheroma with ultrasound attenuation without calcification. A mean attenuation score was created by measuring the angle of attenuation each 1 mm, scoring the angle as 1 to 4 (corresponding to <90°, 90° to 180°, 180° to 270°, or 270° to 360°, respectively), summing the scores, and normalizing for analysis length.

RESULTS - Overall, 284 (78.0%) patients had attenuated plaques; no-reflow occurred in 37 (10.2%). Patients with no-reflow had a higher mean attenuation score (median [interquartile range] 2.2 [0.0 to 2.8] vs. 1.3 [0.7 to 1.8], p < 0.001), lower baseline left ventricular ejection fraction (52.8% [43.2% to 61.5%] vs. 61.4% [52.2% to 68.1%], p = 0.002), and more baseline angiographic thrombus (89.2% vs. 74.1%, p = 0.043) with no differences in post-PCI stent expansion versus patients without no-reflow. Multivariate analysis indicated that mean attenuation score was the strongest predictor of no-reflow. The mean attenuation score that best predicted no-reflow was ≥2 points (90° to 180°, sensitivity of 81.5%, and specificity of 80.5%).

CONCLUSIONS - Attenuated plaque was present in three-quarters of patients with AMI. The amount of attenuated plaque strongly correlated with no-reflow; the larger the attenuated plaque, the greater the likelihood of no-reflow. (Dual Arm Factorial Randomized Trial in Patients w/ST Segment Elevation AMI to Compare the Results of Using Anticoagulation With Either Unfractionated Heparin + Routine GP IIb/IIIa Inhibition or Bivalirudin + Bail-out GP IIb/IIIa Inhibition; and Primary Angioplasty with stent implantation with Either a Slow Rate-release Paclitaxel-eluting Stent [TAXUS™] or Uncoated Bare Metal Stent [EXPRESS2™]; NCT00433966).

Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.