Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis Comparison of one-year clinical outcomes between intravascular ultrasound-guided versus angiography-guided implantation of drug-eluting stents for left main lesions: a single-center analysis of a 1,016-patient cohort rhACE2 Therapy Modifies Bleomycin-Induced Pulmonary Hypertension via Rescue of Vascular Remodeling Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies Ticagrelor Monotherapy Versus Dual-Antiplatelet Therapy After PCI: An Individual Patient-Level Meta-Analysis Comparison of the Efficacy and Safety Outcomes of Edoxaban in 8040 Women Versus 13 065 Men With Atrial Fibrillation in the ENGAGE AF-TIMI 48 Trial Study of Two Dose Regimens of Ticagrelor Compared with Clopidogrel in Patients Undergoing Percutaneous Coronary Intervention for Stable Coronary Artery Disease (STEEL-PCI) Reduced Apolipoprotein M and Adverse Outcomes Across the Spectrum of Human Heart Failure 3-Year Outcomes of the ULTIMATE Trial Comparing Intravascular Ultrasound Versus Angiography-Guided Drug-Eluting Stent Implantation Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease

Original Research2011 Jun;4(3):239-47.

JOURNAL:Circ Cardiovasc Interv. Article Link

Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy

Choi SY, Witzenbichler B, Maehara A et al. Keywords: stents; thrombosis; ultrasonics;myocardial infarction

ABSTRACT


BACKGROUND - Small stent area and residual inflow/outflow disease have been reported as the strongest intravascular ultrasound (IVUS) predictors of early stent thrombosis (ST) in patients with stable angina. IVUS predictors of early ST in patients with acute myocardial infarction have not been studied.


METHODS AND RESULTS - In the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) study, a formal substudy included poststent and 13-month follow-up IVUS at 36 centers. Twelve patients with baseline IVUS who had definite/probable early ST ≤30 days after enrollment were compared with 389 patients without early ST. Significant residual stenosis was a lumen area <4.0 mm(2) with ≥70% plaque burden ≤10 mm from each stent edge. Significant edge dissection was more than medial dissection with lumen area <4 mm(2) or dissection angle ≥60°. Randomization to bivalirudin (P=0.29) or paclitaxel-eluting stent (P=0.74) was not related to early ST. Minimum lumen area was smaller in patients with versus without early ST (4.4 mm(2) [3.6, 6.9] versus 6.7 mm(2) [5.3, 8.0], respectively, P=0.014). Minimum lumen area <5 mm(2), significant residual stenosis, significant stent edge dissection, and significant tissue (plaque/thrombus) protrusion (more than the median that narrowed the lumen to <4 mm(2)) were more prevalent in patients with early ST, but significant acute malapposition (more than the median) was not. Overall, 100% of patients with early ST had at least 1 of these significant features: minimum lumen area <5 mm(2), edge dissection, residual stenosis, or tissue protrusion versus 23% in patients without early ST (P<0.01).

CONCLUSIONS - Smaller final lumen area and inflow/outflow disease (residual stenosis or dissection) but not acute malapposition were related to early ST after acute myocardial infarction intervention.

CLINICAL TRIAL REGISTRATION - URL: http://www.clinicaltrials.gov. Unique identifier: NCT00433966.