CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study Contemporary techniques in percutaneous coronary intervention for bifurcation lesions Treatment of Very Small De Novo Coronary Artery Disease With 2.0 mm Drug-Coated Balloons Showed 1-Year Clinical Outcome Comparable With 2.0 mm Drug-Eluting Stents Influence of Local Myocardial Damage on Index of Microcirculatory Resistance and Fractional Flow Reserve in Target and Nontarget Vascular Territories in a Porcine Microvascular Injury Model Adaptive development of concomitant secondary mitral and tricuspid regurgitation after transcatheter aortic valve replacement Long-term efficacy and safety of drug-coated balloons versus drug-eluting stents for small coronary artery disease (BASKET-SMALL 2): 3-year follow-up of a randomised, non-inferiority trial Optical Coherence Tomography–Defined Plaque Vulnerability in Relation to Functional Stenosis Severity and Microvascular Dysfunction Clinical and angiographic outcomes of coronary dissection after paclitaxel-coated balloon angioplasty for small vessel coronary artery disease Drug-Coated Balloons for Coronary Artery Disease: Third Report of the International DCB Consensus Group Drug-Coated Balloons: A Safe and Effective Alternative to Drug-Eluting Stents in Small Vessel Coronary Artery Disease

Original Research2011 Jun;4(3):239-47.

JOURNAL:Circ Cardiovasc Interv. Article Link

Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy

Choi SY, Witzenbichler B, Maehara A et al. Keywords: stents; thrombosis; ultrasonics;myocardial infarction

ABSTRACT


BACKGROUND - Small stent area and residual inflow/outflow disease have been reported as the strongest intravascular ultrasound (IVUS) predictors of early stent thrombosis (ST) in patients with stable angina. IVUS predictors of early ST in patients with acute myocardial infarction have not been studied.


METHODS AND RESULTS - In the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) study, a formal substudy included poststent and 13-month follow-up IVUS at 36 centers. Twelve patients with baseline IVUS who had definite/probable early ST ≤30 days after enrollment were compared with 389 patients without early ST. Significant residual stenosis was a lumen area <4.0 mm(2) with ≥70% plaque burden ≤10 mm from each stent edge. Significant edge dissection was more than medial dissection with lumen area <4 mm(2) or dissection angle ≥60°. Randomization to bivalirudin (P=0.29) or paclitaxel-eluting stent (P=0.74) was not related to early ST. Minimum lumen area was smaller in patients with versus without early ST (4.4 mm(2) [3.6, 6.9] versus 6.7 mm(2) [5.3, 8.0], respectively, P=0.014). Minimum lumen area <5 mm(2), significant residual stenosis, significant stent edge dissection, and significant tissue (plaque/thrombus) protrusion (more than the median that narrowed the lumen to <4 mm(2)) were more prevalent in patients with early ST, but significant acute malapposition (more than the median) was not. Overall, 100% of patients with early ST had at least 1 of these significant features: minimum lumen area <5 mm(2), edge dissection, residual stenosis, or tissue protrusion versus 23% in patients without early ST (P<0.01).

CONCLUSIONS - Smaller final lumen area and inflow/outflow disease (residual stenosis or dissection) but not acute malapposition were related to early ST after acute myocardial infarction intervention.

CLINICAL TRIAL REGISTRATION - URL: http://www.clinicaltrials.gov. Unique identifier: NCT00433966.